Skip to main content

Chem-Tainer

Chem-Tainer 2800 Gallon Plastic Vertical Liquid Storage Tank

$4,849.00
0
(No reviews yet) Write a Review
Adding to cart… The item has been added
SKU:
TC9598IA
Availability:
In Stock - Ships from nearest manufacturing plant
Weight:
520.00 LBS
Width:
95.00 (in)
Height:
98.00 (in)
Depth:
95.00 (in)
Capacity:
2800 Gallons
Material:
Polyethylene
Color:
Natural White
Diameter:
95"
Lid/Manway:
16"
Specific Gravity:
1.9
Max Temperature:
120° F / 48° C
Certifications:
FDA Approved
Warranty:
3 Year Warranty
Freight Class:
OVS
Manufacturer Part Number:
TC9598IA
Manufacturer:
Chemtainer
Ship Weight:
520 lb
Ship Dimensions:
95" L x 95" W x 98" H (crated)

The Chem-Tainer 2800 Gallon Plastic Vertical Liquid Storage Tank (MPN TC9598IA) is a one-piece rotomolded vertical bulk-liquid tank built to ASTM D1998 standards for atmospheric polyolefin storage vessels.

Design

  • One-piece rotomolded construction eliminates seam-failure and joint-leak paths
  • Built to ASTM D1998 standards for atmospheric polyolefin storage vessels
  • Self-supporting design — no internal or external bracing required for atmospheric service
  • UV-stabilized resin rated for outdoor installation without coating
  • Standard top-manway access for filling, inspection, and gauge installation

Installation

Set on a level concrete pad or compacted base ring sized for the tank footprint plus a 6-inch perimeter clearance. A filled tank at 2800 gallons exerts approximately 23,352 lb of point load at water-service SG. Anchor per ASCE 7 Chapter 13 for seismic and wind-exposed installations.

Common applications

  • Industrial day-tank holding upstream of batch process operations
  • Aqueous-chemistry dilution and dosing-feed staging
  • Wastewater equalization buffer at industrial pretreatment installations
  • Process-water reserve for manufacturing, food processing, and beverage operations
  • Agricultural and commercial bulk-liquid staging
  • General industrial atmospheric storage where SG and chemical compatibility match the OEM rating

Compatibility & compliance

Built to ASTM D1998 standards for atmospheric polyolefin storage tanks. Verify chemical compatibility against the OEM compatibility chart for service beyond water and dilute aqueous chemistry. Not rated for pressurized service, petroleum fuels, or aromatic/chlorinated solvents.

Shipping

Ships LTL freight from the nearest manufacturing plant. ZIP-specific freight quotes are available through the freight estimator or by phoning 866-418-1777 with MPN TC9598IA.