Skip to main content

Snyder Industries

Snyder Industries 1500 Gallon Sulfuric Acid Double Wall Tank

$7,589.00
0
(No reviews yet) Write a Review
Adding to cart… The item has been added
SKU:
SII-5990302N30
Availability:
In Stock - Ships from nearest manufacturing plant
Weight:
950.00 LBS
Width:
93.00 (in)
Height:
76.00 (in)
Depth:
93.00 (in)
Capacity:
1500 Gallons
Material:
HDLPE #880046
Color:
Opaque White
Diameter:
93"
Lid/Manway:
18" Threaded Vented Manway
Specific Gravity:
1.9
Max Temperature:
120° F / 48° C
Certifications:
FDA-compliant resin, NSF 61
Warranty:
3 Year Warranty
Freight Class:
250
Manufacturer Part Number:
5990302N30
Manufacturer:
Snyder Industries
Technical Drawing:
https://onesourceplastics.com/content/snyder-technical-drawings/snyder-1500-gallon-sulfuric-acid-double-wall-tank-5990302n30.pdf
Ship Weight:
950 lb
Ship Dimensions:
93" L x 93" W x 76" H
Lid Size:
18" Threaded Vented Manway

Fifteen hundred gallons named for sulfuric acid

The Snyder 5990302N30 is a 1500 gallon double wall tank, listed on its sheet as a Sulfuric Acid Double Wall Tank, in opaque white at 93 inches long by 93 inches wide by 76 inches tall and 950 pounds empty. That is the maker's own name for the product and we repeat it exactly as it stands; no concentration, no temperature beyond this sheet's own figure and no compatibility claim of any kind follows from it. The material field on this listing is a numbered code rather than a plain material name, so we print no resin grade from it: the tank is polyethylene and that is as far as the sheet lets anybody go. One capacity, one set of overall dimensions, one empty weight and one rating cover the whole assembly. There is no separate inner tank figure, no separate outer containment figure, no annulus dimension and no containment percentage anywhere on the sheet, so none appears on this page. The wall is rated at a specific gravity of 1.9, and the sheet gives 12,510 pounds for 1500 gallons of water at 8.34 pounds per gallon with 23,769 pounds of max contents. The opening is an 18 inch threaded vented manway and the outlet field reads 1 Manway / Lid, which names an opening rather than a pipe size. The service limit is 120 F / 48 C, the warranty is a 3 Year Warranty, and freight is LTL at class 250 with no NMFC number.

Is this the right 1500 gallon tank? Call 866-418-1777 with the liquid, the site and the ceiling height, or get freight to your ZIP and add it to your cart above.

Chowchilla or Lincoln, and what that does to the lane

Start with where it comes from, because on a shipment this size the lane is a real part of the decision. This sheet lists two plants, Chowchilla, California and Lincoln, Nebraska, and two ship-from states. That pairing is the single most useful fact on the page for a buyer east of the Rockies: the plains, the Midwest and much of the South sit on a reasonable lane out of Nebraska, while the West and the Southwest are close to California, so a 1500 gallon vessel is not automatically a coast-to-coast move the way the smaller shells in this family can be. Freight is LTL at class 250, and the shipment is the same 93 by 93 by 76 inches as the tank at 950 pounds. Price your own ZIP before you fix the capacity, because at this size the lane is a material share of what the installation costs and it is the part that changes most between two otherwise identical quotes. The shape follows from the same logic. Seven feet nine each way and six feet four tall is a wide, low object: it will not thread through a building on a pallet truck, so it wants a wall opening, a large shutter or an outdoor position on a prepared base, and it wants a forklift at the offload rather than four people and a plan. What it gives back for that is stability and reach. At 76 inches the manway is within a modest platform rather than a tower, and a low centre of gravity on a broad base is a far easier thing to stand on a pad than a tall narrow vessel of the same volume. Then the ground. Above a 93 inch square footprint sits 12,510 pounds of water at 8.34 pounds per gallon and 23,769 pounds at the published 1.9 rating, so this goes on a ground bearing slab or on a base designed for it, flat and continuous and level across the whole footprint with nothing packed under a corner. Where that base is being poured for the tank, the concrete pad sizing guide for above-ground polyethylene tanks sets out the framework and where its boundary lies. Containment is what you are buying along with the gallons: no kerb to pour, no coating specification, no drainage detail, and nothing about the floor committed permanently to one layout. Where a site has to document how its own containment arrangements are put together, our Snyder Captor double wall containment walkthrough lays out that framework; nothing on this page is a claim that this part number satisfies any rule, and the sheet makes no such claim either. Before you settle on this capacity, read the double wall freeboard sizing guide, because the volume you can actually use is not the nameplate figure, then put your turnover through the tank sizing calculator and take the discipline from the tank sizing guide.

The 1500 shell and the two Captor tanks beside it

Snyder double wall tanks listed on this sheet, 1100 to 1550 gallons
PartGallonsLength x width x heightEmpty weight
5990302N30 (this tank, named Sulfuric Acid, opaque white)150093 x 93 x 76 in950 lb
5990302N42 (named ASTM XLPE)150093 x 93 x 76 in950 lb
5990302N48 (named ASTM XLPE Black)150093 x 93 x 76 in950 lb
5990302N51 (named ASTM Black)150093 x 93 x 76 in950 lb
5470000N48 (named ASTM XLPE Black Captor, narrow and tall)110076 x 76 x 104 in650 lb
5490000N48 (named ASTM XLPE Black Captor, taller again)155076 x 76 x 136 in780 lb

Four listings share this exact 93 by 93 by 76 inch shell at the identical 950 pounds, and what separates them on paper is the name, the colour and the material field the maker assigns to each. We print each name as the sheet gives it and interpret none of them, because a product name is not a specification and reading one as though it were is how a plant ends up with a vessel that was never meant for its duty. Tell us what you are storing and at what strength, and we will tell you which of the four part numbers to order; that is one phone call. This listing is the opaque white one and it is the row a spares list or an existing drawing is most likely to name if the site already runs one. The two Captor rows beneath are not size steps, they are a different tank. Both stand on a 76 inch square plan, well over a foot narrower in each direction than this shell, and both buy their volume in height instead: 1100 gallons at 104 inches and 650 pounds, and 1550 gallons at 136 inches and 780 pounds. That taller row holds a little more than this tank on roughly two thirds of the plan area, at more than eleven feet of height, which is a real answer to a crowded site and a real access problem in exchange. The choice is therefore not about gallons. If your building is low, or if you would rather not own and maintain a permanent access platform, this wide shell is the easier vessel to live with. If floor area is the thing you genuinely cannot spare, price the tall Captor rows properly and cost the platform in at the same time.

Comparing across brands too? Call 866-418-1777; we carry Norwesco, Snyder, Chem-Tainer, Enduraplas and Bushman and will say which one fits, or price the freight first.

Filling through the manway on a ninety-three inch tank

  • The fill opening: an 18 inch threaded vented manway on top is the only opening this sheet publishes, so it is the fill route, the inspection route and the cleaning route at once. Everything that has to go into a 1500 gallon vessel shares it, which makes the fill line, any suction and any instrument you drop in one drawing rather than three separate decisions.
  • Reaching it: the top of the shell is at 76 inches. Design a proper platform with the installation, bring the fill connection down to working level so nobody works off the shell, and settle the receiving procedure at the same time.
  • The vent: the manway is listed as vented, and at this volume that path is doing serious work on every fill and every hard pump down. Keep it clear, inspect it whenever the manway is opened, and never blank it to hold an odour.
  • The outlet field: it reads 1 Manway / Lid and nothing else, and the inlet field is blank. That names an opening rather than a pipe size, so no outlet dimension, thread, bulkhead, flange or valve is claimed on this page. Tell us the duty and the line size and we will confirm what this part number actually carries before a pump is bought.
  • The space between the walls: no monitoring port, no gauge and no alarm is published. At 1500 gallons that arrangement is worth a written procedure with a named owner and a schedule, because the record is the only evidence the second wall is still doing its job.
  • Structure: the sheet publishes no lifting lugs, no ladder lugs, no flange lines, no stand and no level device on this part number.
  • Limits: 120 F / 48 C, a specific gravity rating of 1.9, and a 3 Year Warranty. That is the whole of what this sheet publishes about service.

Name the product and its strength at order time. Every wetted part on a contained tank is chosen against the chemistry, and a second wall does nothing whatsoever for a fitting that was picked from a catalogue default.

Bulk chemical holding at a works with no bund

Fifteen hundred contained gallons is a bulk holding quantity, and it goes to sites that take a full truck drop rather than a part load: coagulant, polymer and treatment chemical storage at municipal water and wastewater works, clean-in-place and sanitising chemical stores on food, beverage and dairy lines, cooling tower and boiler house treatment at scale, plating and surface finishing shops, pulp and paper additive feed, and industrial process storage standing on a yard pad. What they have in common is that constructing a bund for this much product is a project in its own right, and this vessel replaces that project with a purchase order. The economics at this volume sit in the chemistry rather than in the tank: a site holding 1500 gallons buys at a bulk chemical cost per gallon that no tote programme reaches, and the vessel is normally paid for in truck drops rather than in years. Build one habit from the first week: open the space between the walls on a fixed schedule, write down the date and what you saw, and keep that record with the tank rather than in somebody's head.

Setting nine hundred and fifty pounds on a prepared pad

Freight is LTL at class 250 with no NMFC number listed, and the shipping size is given at 93 by 93 by 76 inches at 950 pounds, out of Chowchilla, California or Lincoln, Nebraska. Price the lane to your own ZIP with the freight cost estimator; the listed price is before freight. Plan the offload before the truck is booked rather than on the morning. Nine hundred and fifty pounds is comfortable for a forklift and impossible by hand, and seven feet nine of width will not go through a building, so agree the offload point, the machine and the route to the final position in advance. Take it under the base with the forks approaching square, never by the manway, and set it on the finished, cured, level surface where it is going to live; nothing about a tank this size is repositionable once it is plumbed. Fill it with clean water, hold that 12,510 pound load, and read the manway seal, the base all the way round and the pad beneath it, in that order. Leave the water in overnight where the schedule allows and read the base again in the morning. Then drain it, let it dry, open the space between the walls, look in good light and write the date and the part number on the shell in paint marker. Keep the paperwork from the first fill with the tank as well; strength and date on day one is the baseline every later batch gets compared against. Write the fill date on the manway with a paint marker; it answers the first question anyone asks about a tank.

​‌‌​‌‌‌​‌‌​​​‌​‌​​​‌‌‌​‌​​‌​​​‌‌​‌‌‌​​​‌

Freight and documents

Ships from: Chowchilla, CA; Lincoln, NE. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.

Technical drawing (PDF) for Snyder Industries 5990302N30.

See this tank

Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).

Ready to order?

Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.

Adding to cart… The item has been added