A 3,000 gallon double wall tank at 1.5 specific gravity
The Snyder 5590100N43 is a double wall liquid storage tank: a 3,000 gallon white high density linear polyethylene primary rated for a specific gravity of 1.5, or 37,530 pounds of contents against 25,020 for water, standing inside its own secondary containment in a shell 102 inches across and 142 inches tall, weighing 1,840 pounds. It is bulk storage for a treatment plant's coagulant, brine or hypochlorite with the berm built in, for the plant that cannot pour a basin around an eight and a half foot circle. An 18 inch manway on the primary, and it ships as oversize freight.
Replacing a tank that failed? Call 866-418-1777 with what it held and how long it lasted; or check freight to your ZIP and put the 3000 gallon tank in your cart above.
What the second wall buys
Put a regulated chemical in a single wall tank and the berm has to hold all of it, and at 3,000 gallons that is a concrete basin, a sump, a drain valve that must stay closed, and a rain problem. The containment lives inside the outer shell, so the tank's 102 inch footprint is the entire footprint and the tank can stand inside an occupied building where a spill must never reach a floor drain. A tank's specific gravity rating is the density of the heaviest liquid its wall is sized to hold; alum and ferric solutions, brines and most caustic and hypochlorite as delivered are all lighter than a 1.5 wall is sized for. Work out the usable volume once thermal expansion and the interstice are accounted for with the Captor double wall freeboard sizing guide. The 3,000 gallon vertical tank buyers guide, its companion guide and the 95 by 109 inch guide compare the single wall tanks at this volume, the right comparison only if a berm is already in place. The tank sizing calculator works the volume out from feed rate and delivery interval, and the tank sizing guide covers the reserve.
The grade beside it, and the size below
| Part | Gallons | Diameter x height | Empty weight |
|---|---|---|---|
| 5590100N43 (this tank, 1.5 SG) | 3,000 | 102 x 142 in | 1,840 lb |
| 5590100N45 (1.9 SG) | 3,000 | 102 x 142 in | 1,840 lb |
| 5570100N45 (1.9 SG) | 2,000 | 102 x 103 in | 1,180 lb |
The 5590100N45 is the 1.9 wall in this same shell at the same weight, for ferric at strength and the heavy brines. The 5570100N45 is the 2,000 gallon double wall on this same 102 inch base, 39 inches shorter and 660 pounds lighter, for a lower ceiling.
Ports, plus the level nobody forgets
- Access: 18 inch manway on the primary, 142 inches up; fill down a dip tube, run the vent outside on caustic and hypochlorite, and size it for the unload rate.
- Outlet: one penetration through both walls, a flanged transition, an expansion joint, and a valve on its own support; specify the fitting for the chemical when ordering.
- Service limit: 120 F / 48 C.
Two levels need watching: the primary, with a sender chosen for the chemical, and the interstitial space, monitored with a float or conductivity switch, looked at each shift, and logged each week. Anything found in the space is a primary leak, and the tank comes out of service that day. The outer shell carries nothing, is drilled for nothing, and the space between the walls stores nothing. Full, the tank loads a 102 inch circle to 37,530 pounds at the rating: an engineered, full-contact slab under all of the floor, with straps holding the empty tank against wind and the manway reached from a fixed platform.
The tanker unload
A tanker's pump moves liquid faster than a manway vent can pass air, so either the vent is sized to the unload rate or the fill comes in through its own top bulkhead with a separate vent line. Run the fill pipe to the floor so coagulant or caustic does not free-fall and foam. Somebody stands at the tank for the whole of the first delivery, checking the slab edge, the outlet fitting and the interstitial port as the level rises, and every delivery after that goes in the log with a date and a strength.
Day-to-day duty
Coagulant, brine and hypochlorite bulk storage at water and wastewater plants that cannot build a berm, chemical storage inside occupied buildings, and any regulated liquid of moderate density at plant scale at a site an inspector visits. Label it for the fire inspector and the workplace inspector at once, keep one chemical in it, and keep the manway closed.
From the plant to your site
At 102 inches across and 142 inches long on the deck the 5590100N43 is oversize freight (NMFC 156600) on a flatbed at a lane rate; the freight cost estimator quotes the haul to your ZIP; what is listed is the price before freight. A forklift with long forks or a small crane sets 1,840 pounds on the slab. Prove the primary with water and a dry interstice through the hold; drain and dry before chemical goes in. Write the fill date on the manway with a paint marker; it answers the first question anyone asks about a tank.
Freight and documents
Ships from: Philippi, WV. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 5590100N43.
See this tank
Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).
Product video. Watch the Snyder Industries 3000 Gallon Vertical Double Wall Liquid Storage Tank in White 1.5 S.G. (West Virginia Only) video (71 seconds) with dimensions, fittings and shipping notes.
Ready to order?