6,000 gallons on a 102 inch base, sold without a fitting
The Snyder 7430000C137 is a white high density linear polyethylene vertical liquid storage tank, 102 inches across and 188 inches tall, holding 6,000 gallons at 1,650 pounds. Its wall is rated on the spec sheet for a specific gravity of 1.9, or 95,076 pounds of contents against 50,040 for water, and it ships with no outlet fitting installed: the buyer drills the bulkhead where the pump wants it, in the size and material the liquid calls for, which is how a plant that fits its own tanks prefers to buy. The eight and a half foot base puts a tanker load and a reserve on a pad smaller than the tanker, fifteen and a half feet up. An 18 inch lid on top, and it ships as oversize freight.
Replacing a tank that failed? Call 866-418-1777 with what it held and how long it lasted; or check freight to your ZIP and put the 6000 gallon tank in your cart above.
A tanker and a reserve in a blank tank on the small pad
A factory outlet is at the factory's height, on the factory's side, in polypropylene; a blank tank lets the installer put the bulkhead exactly where the pump sits, in polypropylene, PVDF or a lined fitting as the liquid demands, and add a high-level port, a second outlet or a recirculation return, all with a hole saw and a bulkhead kit. Rotationally molded polyethylene tanks are sized to ASTM D1998, and the sheet rates this wall for liquids nearly twice as dense as water, so brine and coagulant are covered as well as water. Full, it puts 95,076 pounds on a 102 inch circle at the rating: an engineered slab in full contact under the whole floor, per the concrete pad sizing guide, with the empty tank strapped against wind at two heights and the lid reached from a fixed platform with a rail, never a ladder. The 6,000 gallon vertical tank buyers guide compares the shapes at this volume across makers; the tank sizing calculator tells you whether 6,000 gallons covers the draw, and the tank sizing guide covers days of supply.
The blank tanks, and the sizes beside them
| Part | Gallons | Diameter x height | Empty weight |
|---|---|---|---|
| 7430000C137 (this tank, no fitting) | 6,000 | 102 x 188 in | 1,650 lb |
| 7000000C137 (ten foot base, no fitting) | 6,000 | 120 x 132 in | 1,155 lb |
| 8210000C126 (no fitting) | 5,000 | 102 x 154 in | 1,150 lb |
| 1002100C126 | 5,000 | 102 x 154 in | 1,050 lb |
| 7140000C137 (ten foot base) | 6,900 | 120 x 153.5 in | 1,300 lb |
The 7000000C137 is the other blank 6,000, on a 120 inch base at 132 inches, 56 inches lower, for a site with floor and no height. The 8210000C126 is the blank 5,000 on this base, 34 inches lower, beside the 1002100C126 with a factory fitting, and the 7140000C137 holds 6,900 gallons on the ten foot base.
Want the certified one or the plain one? Call 866-418-1777 and say what the inspector asks for; or request a quote on the row you need.
Access, outlet, service limit
- Outlet: none installed. Drill the bulkhead on a flat of the wall, low enough to drain and high enough to clear sediment, with a hole saw sized to the bulkhead kit; a flexible connector and an expansion joint to hard pipe, and the valve supported off the slab.
- Access: 18 inch lid, 188 inches up; filled by truck through a dip tube, vented outside on anything that fumes, and size the vent for a tanker's unload rate.
- Service limit: 120 F / 48 C.
Drill with the tank empty and dry, deburr the hole, and set the bulkhead gasket on the inside of the wall, hand-tight plus a quarter turn; overtightening a bulkhead in polyethylene is the usual first leak. On a tank this tall nobody reads a level by eye; fit a sender read at ground level, and a low-level switch protects the pump. Keep the lid closed against vapor loss, and keep the tank out of direct sun where the liquid is light-sensitive. If winters freeze, wrap or drain the outlet valve and the first pipe run; the body takes ice from the top down without harm.
When the tanker backs in
The driver's pump can deliver faster than the lid vent can breathe, so the vent is sized for the unload rate or the fill goes through a dedicated top bulkhead with its own vent line. The fill pipe runs to the floor so the liquid does not free-fall and foam; on a shell this tall that is a long drop. The first delivery into a new tank is watched from start to finish, with the slab edge and the new outlet fitting checked as the level climbs, and every delivery after that goes in the log with a date and a strength.
Where we ship it
Well storage for a community system that fits its own tanks and has height rather than floor, a rain cistern under a large roof, brine and coagulant delivered by tanker with a reserve, and a fire reserve of the kind the fire-water reservoir design guide describes, where the installer wants the outlet sized to the fire pump and the height gives it a flooded suction. Several of them are the storage stage of a reuse system for roof water and condensate, per the industrial water reuse tank topology article. One liquid per tank, labeled.
How it ships
At 102 inches across and 188 inches long on the deck the 7430000C137 is oversize freight (NMFC 156600) on a flatbed at a lane rate; the freight cost estimator quotes the haul to your ZIP; what is listed is the price before freight. A crane sets 1,650 pounds upright on the slab; a forklift gets it off the truck but cannot stand it up. Drill and fit the outlet, then fill it to the lid once, hold it, and check the fitting for a weep before the pump goes on. Keep one spare gasket for the outlet fitting on the shelf; it is the part that fails on a holiday.
Freight and documents
Ships from: Chowchilla, CA; Lincoln, NE; Philippi, WV. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 7430000C137.
Ready to order?