Snyder Industries 5000 Gallon Plastic Vertical Liquid Storage Tank Without Fitting 1.9 s.g.

$8,434.71
0
(No reviews yet) Write a Review
Adding to cart… The item has been added
SKU:
SII-8210000C126
Availability:
In Stock - Ships from nearest manufacturing plant
Weight:
1,150.00 LBS
Width:
102.00 (in)
Height:
154.00 (in)
Depth:
102.00 (in)
Capacity:
5000 Gallons
Material:
High Density Linear Polyethylene
Color:
White
Diameter:
102"
Lid/Manway:
18"
Specific Gravity:
1.9
Max Temperature:
120 F/ 48 C
Certifications:
2285,2282
Freight Class:
OVS
NMFC Code:
156600
Manufacturer Part Number:
8210000C126
Manufacturer:
Snyder Industries
Technical Drawing:
https://onesourceplastics.com/content/snyder-technical-drawings/snyder-industries-5000-gallon-plastic-vertical-liquid-storage-tank-without-fitting-1-9-s-g-8210000c126.pdf
Ship Weight:
1150 lb
Ship Dimensions:
154" L x 102" W x 102" H (crated)
Specific Gravity Rating:
1.9
Lid Size:
18"

5,000 gallons on a 102 inch base, sold without a fitting

The Snyder 8210000C126 is a white high density linear polyethylene vertical liquid storage tank, 102 inches across and 154 inches tall, holding 5,000 gallons at 1,150 pounds. Its wall is rated on the spec sheet for a specific gravity of 1.9, or 79,230 pounds of contents against 41,700 for water, and it ships with no outlet fitting installed: the buyer drills the bulkhead where the pump wants it, in the size and material the liquid calls for, which is how a plant that fits its own tanks prefers to buy. An 18 inch lid on top, and it ships as oversize freight.

Two ways to buy. Add it to your cart above with freight quoted to your ZIP, or request a written quote for a job that needs paperwork.

A tanker load in a blank tank on the small pad

A factory outlet is at the factory's height, on the factory's side, in polypropylene; a blank tank lets the installer put the bulkhead exactly where the pump sits, in polypropylene, PVDF or a lined fitting as the liquid demands, and add a high-level port or a second outlet, all with a hole saw and a bulkhead kit. Rotationally molded polyethylene tanks are sized to ASTM D1998, and the sheet rates this wall for liquids nearly twice as dense as water, so brine and coagulant are covered as well as water. Full, it puts 79,230 pounds on a 102 inch circle at the rating: an engineered slab bearing under the entire floor, the empty tank strapped down against wind and the lid reached from a fixed platform. The 5,000 gallon vertical tank buyers guide walks through the competing shapes at this volume; the tank sizing calculator tells you whether 5,000 gallons covers the draw, and the tank sizing guide covers days of supply.

The 102 x 154 inch tanks, and the sizes beside them

Snyder vertical tanks, 4,400 to 6,000 gallons
PartGallonsDiameter x heightEmpty weight
8210000C126 (this tank, no fitting)5,000102 x 154 in1,150 lb
1002100C1265,000102 x 154 in1,050 lb
1002100N30 (sulfuric grade)5,000102 x 154 in1,050 lb
8210000N43 (1.5 SG)4,650102 x 154 in1,200 lb
8210000N45 (1.9 SG)4,650102 x 154 in1,613 lb
5210000N30 (tall, sulfuric grade)4,40090 x 182 in1,450 lb
7000000C137 (ten foot base, no fitting)6,000120 x 132 in1,155 lb

The 1002100C126 is the other general-grade 5,000 in this shell, 100 pounds lighter, and the 1002100N30 the sulfuric acid resin. The 8210000N43 and N45 are the rated 1.5 and 1.9 walls in this same mold, listed at 4,650 gallons, for a job that wants the wall spelled out; the 5210000N30 stands 4,400 gallons of sulfuric resin on a 90 inch base, and the 7000000C137 is the other blank tank, 6,000 gallons on a ten foot base under eleven feet.

Torn between two rows? Call 866-418-1777 with the liquid and the ceiling height, or ask for a quote on both and compare the freight.

The fittings list

  • Outlet: none installed. Drill the bulkhead on a flat of the wall, low enough to drain and high enough to clear sediment, with a hole saw sized to the bulkhead kit; a flexible connector and an expansion joint to hard pipe, and the valve supported off the slab.
  • Access: 18 inch lid, 154 inches up; filled by truck through a dip tube, vented outside on anything that fumes, and size the vent for a tanker's unload rate.
  • Service limit: 120 F / 48 C.

Drill with the tank empty and dry, deburr the hole, and set the bulkhead gasket on the inside of the wall, hand-tight plus a quarter turn; overtightening a bulkhead in polyethylene is the usual first leak. The white wall shows the level in daylight; fit a sender read at ground level so nobody climbs for a number, and fit a low-level float switch so a pump never runs dry. Keep the lid closed against vapor loss, and keep the tank out of direct sun where the liquid is light-sensitive. In a cold climate the outlet valve and the first run of pipe are insulated or drained; the body takes ice from the top down without harm.

Vent first, then fill

The driver's pump can deliver faster than the lid vent can breathe, so the vent is sized for the unload rate or the fill goes through a dedicated top bulkhead with its own vent line. The fill pipe runs to the floor so the liquid does not free-fall and foam. The first delivery into a new tank is watched from start to finish, with the slab edge and the new outlet fitting checked as the level climbs, and each delivery after it is logged with its date and strength.

What goes in it

Well storage for a community system that fits its own tanks, a rain cistern under a large roof, brine and coagulant delivered by tanker at a plant with its own fitting standard, and a fire reserve of the kind the fire-water reservoir design guide describes, where the installer wants the outlet sized to the fire pump rather than to a catalog. One liquid per tank, labeled.

Getting it off the truck

At 102 inches across and 154 inches long on the deck the 8210000C126 is oversize freight (NMFC 156600) on a flatbed at a lane rate; the freight cost estimator prices the move to your ZIP, and the price on this page is before freight. A forklift with long forks or a small crane sets 1,150 pounds on the slab. Drill and fit the outlet, then fill it to the lid once, hold it, and check the fitting for a weep before the pump goes on. The first fill is the only cheap time to find a problem, so do it in daylight with someone watching the base.

Freight and documents

Ships from: Marked Tree, AR. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.

Technical drawing (PDF) for Snyder Industries 8210000C126.

Ready to order?

Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.

Adding to cart… The item has been added