Skip to main content

Snyder Industries

Snyder Industries 4000 Gallon ASTM Black Double Wall Tank

MSRP: $31,630.00
$29,599.00
(You save $2,031.00 )
0
(No reviews yet) Write a Review
Adding to cart… The item has been added
SKU:
5610000N51
Availability:
In Stock - Ships from nearest manufacturing plant
Weight:
3,200.00 LBS
Width:
102.00 (in)
Height:
178.00 (in)
Depth:
102.00 (in)
Capacity:
4000 Gallons
Material:
High Density Linear Polyethylene
Color:
Black
Diameter:
102"
Lid/Manway:
18" Threaded Vented Manway
Specific Gravity:
1.9
Max Temperature:
120° F / 48° C
Certifications:
FDA-compliant resin, NSF 61
Warranty:
3 Year Warranty
Freight Class:
250
Manufacturer Part Number:
5610000N51
Manufacturer:
Snyder Industries
Technical Drawing:
https://onesourceplastics.com/content/tech-drawings/5610000n51.pdf
Ship Weight:
3200 lb
Ship Dimensions:
102" L x 102" W x 178" H (crated)

Four thousand gallons of contained black wall, rated 1.9

The Snyder 5610000N51 is a 4000 gallon double wall tank, named on its own sheet as an ASTM Black double wall tank; those name words are the maker's name for the product and nothing is claimed from them. The material field reads high density linear polyethylene and the colour field reads black. The shell is listed at 102 inches long by 102 inches wide by 178 inches tall and 3,200 pounds empty. The sheet publishes one capacity, one set of overall dimensions, one empty weight and one rating for the whole assembly: there is no separate inner tank figure, no separate outer containment figure, no annulus dimension and no containment percentage on it, so none appears on this page. The wall is rated at a specific gravity of 1.9, and the sheet gives 33,360 pounds for 4,000 gallons of water at 8.34 pounds per gallon with 63,384 pounds of maximum contents. The only opening published is an 18 inch threaded vented manway. The outlet field reads "1 Manway / Lid", which names an opening rather than a pipe size, and the inlet field is empty. The service limit on this sheet is 120 F / 48 C and the warranty is listed as a 3 Year Warranty. Freight is LTL at class 250 with no NMFC number, moulded at Lincoln, Nebraska.

Want it on your site? Get LTL freight to your ZIP, add it to your cart above, or call 866-418-1777 and a tank specialist will confirm the fit.

The duty that buys a 1.9 rating at four thousand gallons

Start with the job rather than the tank. Four thousand contained gallons is what a site buys when it has stopped handling totes and started taking a bulk hose delivery, and when the surface the vessel stands on is somewhere a release would be expensive: a treatment building floor that drains to the works, a plant room over an occupied space, a yard that drains to a watercourse. Water and wastewater treatment plants, food, beverage and dairy processing, power and boiler house chemistry, pulp, paper and metals, mine site water treatment and ag retail all buy this size for the same reason, and it is never the tank they are buying. It is the containment, arriving as one item on one footprint instead of as a poured bund with its own drawings, its own drainage question and its own maintenance. What separates this part number inside that duty is the rating line. At a specific gravity of 1.9 this sheet carries 63,384 pounds of maximum contents against 33,360 pounds of plain water at 8.34 pounds per gallon, which means the wall is listed for a product appreciably denser than water at the full 4,000 gallons. If what you are dosing is heavy, this is the listing to order and there is no sensible substitution for it; if it is water or close to water, you are paying to freight and lift wall you will never use. That decision comes off the rating line and the chemistry you describe to us, never off the suffix, which the sheet does not explain and neither will we. The second thing this sheet gives you is a black wall, which keeps daylight off the contents and costs you any chance of reading a level through the shell. On a vessel whose only published opening is a manway at 178 inches, decide the level arrangement before the tank is set rather than after somebody guesses. The ground underneath is the rest of the decision. Close to fifteen feet of tank on an eight and a half foot square plan concentrates 33,360 pounds of water, or 63,384 pounds at the published rating, onto very little ground, so the surface has to be flat, continuous and level across the whole 102 inch footprint, never two rails and never packed up at one corner. Size the volume honestly before you order: the usable capacity of a contained tank is not the nameplate figure, which the Captor double wall freeboard sizing guide works through on thermal expansion, chemistry and density. Then put your own consumption and drop quantity through the tank sizing calculator and take the freeboard discipline from the tank sizing guide.

One 102 inch plan from thirty-five hundred to forty-five hundred gallons

Snyder double wall tanks listed on this sheet
PartName on the sheetGallonsSize and empty weight
5610000N51this tank, ASTM Black, rated 1.94000102 x 102 x 178 in, 3,200 lb
5610000N30Sulfuric Acid, same shell, same listed weight4000102 x 102 x 178 in, 3,200 lb
5610000N42ASTM XLPE, same shell, same listed weight4000102 x 102 x 178 in, 3,200 lb
5610000N40ASTM XLPE, same shell, lighter listing4000102 x 102 x 178 in, 2,400 lb
5600000N30Sulfuric Acid Captor, shorter shell3500102 x 102 x 158 in, 2,500 lb
5620000N30Sulfuric Acid, taller shell4500102 x 102 x 197 in, 3,800 lb

The first four rows are one moulding sold under several names, and the sheet separates them by listed weight alone: this tank, 5610000N30 and 5610000N42 at 3,200 pounds, 5610000N40 at 2,400. No sheet in this family says what any of the codes mean, so no interpretation is offered here; describe the product and the strength and we will name the part number against it. What the table does settle cleanly is the size question, because every shell in this family stands on the identical 102 inch square. Gallons are bought purely in height. 5600000N30 holds 3,500 gallons at 158 inches and 2,500 pounds; this tank holds 4,000 at 178 inches; 5620000N30 holds 4,500 at 197 inches and 3,800 pounds. Nothing about the pad, the bay layout or the footprint changes as you move between them, which means the constraint that picks your row is the clear height at the final position once a platform and a fill arrangement are allowed for above the manway, and after that the delivery interval you are willing to live with. Measure the height first, then count the truck drops, then buy the tallest row that satisfies both. Fewer, larger drops usually improve the bulk chemical cost per gallon, and over a decade that arithmetic dwarfs the difference between one shell and the next.

Picked the 4000 gallon tank? Add it to your cart above; freight is quoted to your ZIP before you pay anything.

The suction line, the pump and one 18 inch manway

  • The discharge and suction path: this sheet publishes one opening and no outlet dimension, so the pump arrangement is designed rather than assumed. On tanks configured this way the usual answer is a suction line dropped through the manway to a pump standing alongside, with the foot of the line set clear of the bottom so the last settled inch is not the first thing it lifts. Keep the suction short, keep it rigid where you can, and support the hose off a frame rather than off the manway rim.
  • Priming and low level: a pump that runs dry on a vessel holding 33,360 pounds of water is a pump that fails on the day of a delivery, so set your stop level, mark it, and protect it with a low level cut-out chosen with the pump. On a black shell nothing can be read through the wall, so that protection is instrumentation rather than eyesight.
  • The outlet field: it reads "1 Manway / Lid" and nothing else, and the inlet field is empty. That names an opening, not a pipe size, so no outlet dimension, thread, bulkhead, flange or valve is claimed here. Give us the duty, the line size and the pump and we will confirm what this part number carries before pipe is bought.
  • The manway: 18 inches, threaded and vented, and the only opening the sheet publishes. It is the fill route, the inspection route and the cleaning route at once, and it sits at 178 inches, which makes a fixed ladder, a platform and a fall protection arrangement part of the installation rather than an afterthought.
  • The vent: the manway is listed as vented, and that path is the wall's protection every time a delivery pushes air out and every time a pump draws the level down. Keep it clear, inspect it whenever the manway is open, and never blank or restrict it.
  • Structure: the sheet lists ladder lugs and 4 flange lines on this shell and publishes no lifting lug count.
  • The space between the walls: no monitoring port, gauge or alarm is published, so how that space is watched and recorded is specified separately.
  • Limits: 120 F / 48 C, a specific gravity rating of 1.9, and a 3 Year Warranty. That is the whole of what this sheet publishes about service.

Name the product and its strength at order time, because every wetted part is chosen against the chemistry and a fitting picked from a catalogue default is the one route a release can take out of a tank that otherwise has two walls.

Plant dosing where the floor is the reason for containment

Four thousand gallons at the heavier rating goes to the plants that dose continuously and receive in bulk: municipal water and wastewater treatment, industrial process chemical holding, power generation and large boiler house chemistry, food, beverage and dairy plants, metal finishing, pulp and paper, mine and quarry water treatment, and agricultural retail. In all of them the second wall is bought for the surface underneath rather than for the liquid, and the value it returns is the evidence that nothing has left the first wall, which means an inspection schedule with dates written down from week one. Three pieces of reading pay for themselves before the order. The hardest service a polyethylene wall sees is at the vapour line rather than under the liquid, which the wall thickness at the vapour saturated headspace guide explains, and it is the reason an inspection done from the liquid side misses what matters. Where the enquiry is really about private fire water storage rather than chemical feed, that is a different duty sized by different rules and the fire water reservoir design guide for rural and remote sites is where it starts; nothing on this page is a claim about that use. Agree the receiving procedure when you buy the tank rather than on the first delivery: where the driver connects, who watches the fill, what the stop level is and what happens if the vent is obstructed.

Thirty-two hundred pounds, Lincoln, class 250

Lincoln, Nebraska is the only plant this sheet names and it publishes no ship-from state field at all, so the plant is what we print and nothing further is claimed about the lane. Freight is LTL at class 250 with no NMFC number, and the crated load is given at 102 by 102 by 178 inches at 3,200 pounds. Price your own lane to your ZIP with the freight cost estimator; the listed price is before freight. The sheet publishes no crane specification, no rigging plan, no permit and no escort requirement, so none is stated here; what it does give you is an envelope close to fifteen feet tall and eight and a half feet square, and that is what the route and the offloading equipment have to answer. Walk the route before the truck is booked: gate frames, overhead services, the door lintel and the turning room at the far end stop more deliveries than weight ever does, and confirm the equipment at your end has reach as well as rating. Take it under the base and never lift it by the manway. Set it on the finished, cured, level surface in its final position before a single pipe is connected, prove it plumb in two directions while it is empty, then fill it with clean water and hold that 33,360 pound load while you read the manway seal, the base all the way round and the pad beneath it. Drain it, let it dry, open the space between the walls, look in good light and write the date on the shell in paint marker with the part number beside it. On a black tank, stencil the contents and your stop level on the outside the same day, because nobody is ever going to see the liquid through this wall. Keep the delivery paperwork with the tank; the serial number on the shell is what a warranty claim starts from.

Freight and documents

Ships from: Lincoln, NE. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.

Technical drawing (PDF) for Snyder Industries 5610000N51.

See this tank

Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).

Ready to order?

Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.

Adding to cart… The item has been added