Four thousand five hundred gallons, 102 inches across
The Snyder 5620000N30 is a 4,500 gallon double wall tank that Snyder names Sulfuric Acid, described here exactly as the maker names it: the sheet publishes no concentration, no acid strength and no compatibility statement, so this page makes none. The shell is opaque white high density linear polyethylene, 102 inches long by 102 inches wide by 197 inches tall, 3,800 pounds empty. One capacity, one set of overall dimensions, one empty weight and one rating are published for the whole assembly; there is no separate inner tank figure, no separate outer containment figure, no annulus dimension and no containment percentage on the sheet, so none appears here. The wall is rated at a specific gravity of 1.9, and the sheet gives 37,530 pounds for 4,500 gallons of water at 8.34 pounds per gallon with 71,307 pounds of max contents. The published opening is an 18 inch threaded vented manway; the outlet field reads "1 Manway / Lid", which names an opening rather than a pipe size, and the inlet field is blank. The service limit is 120 F / 48 C and the warranty is a 3 Year Warranty, with no maintenance interval published. The ship mode is LTL at class 250 with no NMFC number, moulded at Lincoln, Nebraska.
Engineer on the job? Request a written quote with the spec attached, or get freight to your ZIP and add to cart above; 866-418-1777 answers the technical questions.
Height, not width, is what you buy at this step
Everything on this sheet except one row stands on a 102 inch square, so the family is a column rather than a range and you are choosing a height. This tank is 197 inches. Below it the sheet publishes a 4,000 gallon at 178 inches and 3,200 pounds; above it a 5,000 gallon at 216 inches and 3,600 pounds. Same plan, same pad, same approach, same bearing area, three heights. That makes this an unusually clean decision and it moves the whole question onto your building and your consumption instead of onto civil works. Look up before you look around: an overhead service run, a canopy edge, a crane rail, a power line or a planning height is what normally decides between the three, and if none of those bind, the delivery schedule should. This 4,500 is the middle of the column and it earns that position by holding a useful working stock on a footprint under nine feet square, which fits inside a great many existing bunded areas and equipment yards without moving anything. The slab still needs designing. One hundred and ninety-seven inches of vessel on a 102 inch square carries 37,530 pounds of water, or 71,307 pounds at the published 1.9 rating, on a modest patch of ground, and a tall tank on a small plan concentrates that load rather than spreading it. Start from the concrete pad sizing guide for above ground polyethylene tanks, get the slab specified and cured before the tank is scheduled, and confirm the subgrade rather than assuming it. Then take the volume seriously: the usable capacity of a contained tank is not its nameplate figure, which the Captor double wall freeboard sizing guide works through on thermal expansion, chemistry and density, and run your own numbers through the tank sizing calculator with the freeboard discipline from the tank sizing guide.
The 102 inch column from 4,000 to 5,000
| Part | Name on the sheet | Gallons | Size and empty weight |
|---|---|---|---|
| 5620000N30 | this tank, Sulfuric Acid, opaque white | 4,500 | 102 x 102 x 197 in, 3,800 lb |
| 5620000N40 | ASTM XLPE | 4,500 | 102 x 102 x 197 in, 3,000 lb |
| 5620000N42 | ASTM XLPE (same name, heavier) | 4,500 | 102 x 102 x 197 in, 3,800 lb |
| 5620000N46 | ASTM XLPE Black | 4,500 | 102 x 102 x 197 in, 3,000 lb |
| 5610000N30 | Sulfuric Acid, same plan, shorter | 4,000 | 102 x 102 x 178 in, 3,200 lb |
| 5630000N40 | ASTM XLPE, same plan, taller | 5,000 | 102 x 102 x 216 in, 3,600 lb |
Four part numbers share this 102 by 102 by 197 inch shell, and two of them carry the same name at different empty weights: 5620000N40 at 3,000 pounds and 5620000N42 at 3,800. Both are printed exactly as the sheet gives them and neither is explained, because the sheet explains neither and we would rather leave an honest gap than fill it with a guess. Order against the part number your drawing, your installation record or your spares list already names, and tell us the product and the strength so the listing can be confirmed before a quote goes out. The two capacity rows are where this page is genuinely useful. The 4,000 gallon is this tank with nineteen inches taken off the top, on the identical plan at 3,200 pounds. The 5,000 gallon adds height on the same plan at 3,600 pounds. None of the three changes the pad, the approach, the lifting arrangement or the ground you have to prepare, so the only real inputs are your overhead clearance and how often you want a truck on site. Fewer, larger drops usually beat more frequent small ones once the tank is paid for, and that is an arithmetic question rather than a preference. Work it out on a year of consumption before you settle the height.
Height or floor the limit? The table has both shapes; freight to your ZIP is quoted on each row, or call 866-418-1777 with the site.
One opening on top and no published outlet size
- The vent: the manway is listed as threaded and vented. That path is the wall's protection while a bulk delivery pushes air out and while a pump pulls the level down, and on a tall vessel on a small plan the level moves quickly for a given flow. Keep it clear, inspect it whenever the manway is open, never restrict it.
- The manway: 18 inches, and the only opening published on this sheet. Fill, inspection and cleaning all share it, and it is wide enough to work a lance and see the wall properly.
- Reaching it: the top is at 197 inches, over sixteen feet. A fixed ladder or platform, a fall protection arrangement and a fill connection brought down to ground level belong in the installation drawing rather than being sorted out on the day the first truck arrives.
- The outlet field: "1 Manway / Lid" and nothing more, with the inlet field blank. That is the name of an opening rather than a pipe size, and no outlet dimension, thread, bulkhead, flange or valve is published on this sheet or claimed on this page. Give us the line size, the valve type and the pump and we will confirm what this part number carries before anything is ordered.
- The space between the walls: no monitoring port, gauge or alarm is published. That arrangement is specified separately, and the point of a second barrier is being able to show it is still empty.
- Structure: the sheet publishes no lifting lugs, no ladder lugs and no flange lines on this part number.
- Limits: 120 F / 48 C, a specific gravity rating of 1.9, and a 3 Year Warranty, with no maintenance interval published.
Name the product and its strength when you order. On a contained tank the fitting is the single part of the system that two walls do nothing for, and a generic choice there is the one that undoes the purchase.
Plants that buy by the truck and dose by the day
Four thousand five hundred contained gallons suits operations that take a bulk delivery and then feed it out steadily: municipal water and wastewater treatment, metal finishing and plating lines, food and beverage processing, cooling water and boiler chemistry at a working plant, mining and aggregate reagent feed, pulp and paper additive storage, and distribution depots holding a working stock between arrivals. On a footprint under nine feet square it fits into existing equipment yards and inside bunded areas that were built for something else, which is often what makes the project possible at all. And the containment travels with the tank, so a line that moves does not leave a concrete structure behind it. Where a site is preparing its own spill prevention paperwork around contained bulk storage, our Captor double wall spill planning walkthrough is the place to start; nothing here is a claim that a particular rule is satisfied by this part number. Decide who watches the fill before the first delivery, not during it.
Three thousand eight hundred pounds on the Nebraska lane
Lincoln, Nebraska is the only plant on this sheet and Nebraska the only ship-from state, so the plains and the Midwest are the short lane and everything else is a planned movement. The ship mode reads LTL at class 250 with no NMFC number, and the shipping dimensions are 102 by 102 by 197 inches at 3,800 pounds. Price the lane to your own ZIP with the freight cost estimator; the listed price is before freight. The receiving end needs arranging in advance: lifting equipment with reach for a vessel over sixteen feet tall, a clear approach for the truck, firm ground for the lift, and a pad already poured and cured rather than being formed around the tank. Lift under the base by the rigger's arrangement and never by the manway. Set it plumb, check it in two directions, confirm the full 102 inch footprint is bearing evenly, and connect nothing until that is signed off. Fill it with clean water, hold the 37,530 pound load and read the manway seal, the whole base line and the slab under it while it is loaded. Drain it, let it dry, open the space between the walls and record the date. Then measure and write down the clearance from the top of the manway to whatever is above it; that figure is what tells the next engineer whether the 5,000 gallon would ever have fitted. The vent screen is the cheapest part on the tank and the one that saves it; look at it every time the manway opens.
Freight and documents
Ships from: Lincoln, NE. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 5620000N30.
See this tank
Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).
Ready to order?
Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.