Skip to main content

Snyder Industries

Snyder Industries 4500 Gallon ASTM XLPE Black Double Wall Tank

$31,399.00
0
(No reviews yet) Write a Review
Adding to cart… The item has been added
SKU:
SII-5620000N46
Availability:
In Stock - Ships from nearest manufacturing plant
Weight:
3,000.00 LBS
Width:
102.00 (in)
Height:
197.00 (in)
Depth:
102.00 (in)
Capacity:
4500 Gallons
Material:
Crosslinked Linear Polyethylene
Color:
Black
Diameter:
102"
Lid/Manway:
18" Threaded Vented Manway
Specific Gravity:
1.5
Max Temperature:
140° F / 60° C
Certifications:
FDA-compliant resin, NSF 61
Warranty:
3 Year Warranty
Freight Class:
250
Manufacturer Part Number:
5620000N46
Manufacturer:
Snyder Industries
Technical Drawing:
https://onesourceplastics.com/content/tech-drawings/5620000n46.pdf
Ship Weight:
3000 lb
Ship Dimensions:
102" L x 102" W x 197" H
Lid Size:
18" Threaded Vented Manway
Swatch Group:
GRP-14769
Color Options:
5620000N40 | Natural White Standard 1.5 | /snyder-industries-4500-gallon-astm-xlpe-double-wall-tank-5620000n40/
Specific Gravity Options:
5620000N42 | Natural White Heavy Duty 1.9 | /snyder-industries-4500-gallon-astm-xlpe-double-wall-tank-5620000n42/ 5620000N48 | Black Heavy Duty 1.9 | /snyder-industries-4500-gallon-astm-xlpe-black-double-wall-tank-5620000n48/

Cross-linked forty-five hundred, 1.5 rating, listed to 140 F / 60 C

This is the lightest of the 4,500 gallon listings on this shell and the one whose sheet pairs a cross-linked wall with the higher service limit. The Snyder 5620000N46 is a 4500 gallon double wall tank, named by the maker as an ASTM XLPE Black double wall tank, and the name words are repeated as a name only. The material field reads crosslinked linear polyethylene and the colour field reads black. The shell is listed at 102 inches long by 102 inches wide by 197 inches tall and 3,000 pounds empty. One capacity, one set of overall dimensions, one empty weight and one rating are published for the whole assembly: there is no separate inner tank figure, no separate outer containment figure, no annulus dimension and no containment percentage on this sheet, so none appears on this page. The wall is rated at a specific gravity of 1.5, and the sheet gives 37,530 pounds for 4,500 gallons of water at 8.34 pounds per gallon with 56,295 pounds of maximum contents. The only opening is an 18 inch threaded vented manway; the outlet field reads "1 Manway / Lid", an opening and not a pipe size, and the inlet field is empty. The service limit is 140 F / 60 C and the warranty is a 3 Year Warranty. No lifting lug count, ladder lug or flange line is published. Freight is LTL at class 250 with no NMFC number out of Lincoln, Nebraska.

Want it on the pad this month? Check freight to your ZIP, add it to your cart above, and 866-418-1777 will confirm the ship date.

Freight on the lightest listing in the 197 inch group

Begin with the lane, because it is the part of this purchase people plan last and regret first. One plant is named on this sheet, Lincoln, Nebraska, and no ship-from state field is published at all, so the haul runs from Lincoln to your gate and nothing further is claimed about it here. The shipping size is 102 inches by 102 inches by 197 inches at 3,000 pounds moving LTL at class 250 with no NMFC number, which is the lighter of the two weights carried on this shell and the easiest arrival in the group. Price the lane to your own ZIP with the freight cost estimator; the listed price is before freight. Weight is the half of the problem that gets easier here; geometry is the half that does not, so the route still has to swallow better than sixteen feet of shipment on an eight and a half foot square, and that is measured with a tape before the truck is booked rather than guessed from memory. What puts this part number on the order is the pair of numbers on its own sheet. The service limit is 140 F / 60 C, the higher of the two limits available in this shell, which is what you hold against the real worst case: heated rinse water, clean-in-place solution held at temperature, a bay that runs hot under a steel roof, a product that does not arrive cold. The rating is a specific gravity of 1.5, carrying 56,295 pounds of maximum contents against 37,530 pounds of plain water at 8.34 pounds per gallon, so this is margin over water rather than provision for something much denser. Warm and light is a narrower specification than it sounds, and this listing is written for exactly it. The material field reads crosslinked linear polyethylene, which is the whole of what this page will say about resin, because a resin word is not a compatibility statement. Colour is black, so nothing is readable through the wall and the level instrument belongs on the specification rather than on a wish list. And the ground carries what the liquid weighs regardless of how light the shipment was: 37,530 pounds on a 102 inch square wants a flat, continuous, cured and level surface under the entire footprint, never two rails and never packing at one corner. Put your own consumption and drop quantity through the tank sizing calculator and take the freeboard discipline from the tank sizing guide before the capacity is fixed, because a contained tank does not hand you the nameplate figure.

Where the lighter listing sits in the family

Snyder double wall tanks listed on this sheet
PartGallonsLength x width x heightEmpty weight
5620000N46 (this tank, named ASTM XLPE Black, rated 1.5, listed to 140 F / 60 C)4500102 x 102 x 197 in3,000 lb
5620000N40 (named ASTM XLPE, same listed weight)4500102 x 102 x 197 in3,000 lb
5620000N42 (named ASTM XLPE, heavier listing)4500102 x 102 x 197 in3,800 lb
5620000N30 (named Sulfuric Acid, heavier listing)4500102 x 102 x 197 in3,800 lb
5610000N30 (one capacity step down)4000102 x 102 x 178 in3,200 lb
5630000N40 (one capacity step up)5000102 x 102 x 216 in3,600 lb

This tank and 5620000N40 are the 3,000 pound listings in the group; 5620000N42 and 5620000N30 are listed at 3,800 pounds on the identical shell. The sheet gives both figures without explaining either, and inventing an explanation would be worse than leaving the question where it belongs, which is with the product you are storing. Send us the name and the strength of that product and we will confirm which listing matches it before anything is quoted. Notice one real advantage of the lighter pair, though: on a vessel this size the empty weight is what your yard has to handle, while the load on the pad is set by the water either way, so choosing the lighter listing where the duty allows makes delivery day easier without changing a single thing about the civil work. The two capacity rows work the way they do across this whole family, in height alone. Nineteen inches shorter takes you to 4,000 gallons at 3,200 pounds; nineteen inches taller takes you to 5,000 at 3,600. The 102 inch square never moves, so the pad you pour serves any of the three and the decision gets made with a tape measure held up to the roof steel and a calendar showing how often you want a truck at the gate.

Which wall for your chemical? Call 866-418-1777 with the name and the concentration, or send a quote request and we will pick the row.

The manway is the fill point, the inspection port and the clean-out

  • The opening: one 18 inch threaded vented manway, and that is the whole of what this sheet publishes. It is how the product goes in, how anybody looks inside, and how the vessel gets rinsed, so all three jobs are planned around one hole before the tank is set.
  • Where it sits: at the top of a 197 inch column, so a fixed ladder, a platform and a fall protection arrangement are designed with the installation, and the clear height has to allow for them above the shell.
  • The vent: listed as part of the manway. A warm headspace moves more air for the same change in level, so never blank or restrict it, and inspect it whenever the manway is open.
  • Warm service at the fittings: with the sheet at 140 F / 60 C, seals, gasket material, valve seats and any flexible connection are chosen against temperature as well as chemistry. A warm-service weep almost always starts at a fitting, not at the wall.
  • The outlet field: it reads "1 Manway / Lid" with the inlet field empty. That is the name of an opening and not a pipe size, so no outlet dimension, thread, flange or valve is claimed on this page. Tell us the duty, the working temperature and the line size and we will confirm what this part number carries.
  • Level and prime: black wall, no visual level. Set the stop level, mark it, and protect it with a low level cut-out chosen alongside the pump rather than after it.
  • Structure: no lifting lug count, ladder lug or flange line is published on this sheet, so none is claimed.
  • The space between the walls: no monitoring port, gauge or alarm is published, so how that space is watched and recorded is specified separately.
  • Limits: 140 F / 60 C, a specific gravity rating of 1.5, and a 3 Year Warranty. That is the whole of what this sheet publishes about service.

Give us the product, its strength and its working temperature at order time, and every wetted part is chosen once against the real duty instead of replaced after the first warm summer.

Warm rinse and make-up duty at forty-five hundred gallons

A plant that stores something close to water in density but runs it warm is the buyer here: clean-in-place and wash-down supply in food, beverage and dairy work, heated rinse water on process lines, boiler and cooling tower make-up, dilute treatment solution at a water or wastewater works, laundry and industrial wash service, and process water holding in a bay that gets hot under a steel roof. In all of them the containment is bought for the surface underneath, not for the liquid, and what it returns is evidence rather than protection you can feel: a written record, kept from week one, that the first wall has not leaked. Warm duty also decides where you look. A polyethylene wall works hardest at the vapour line rather than under the liquid, which the wall thickness at the vapour saturated headspace guide explains, and it is the reason an inspection carried out from the liquid side misses what matters most. Where the enquiry behind a tank this size is really private fire water storage rather than process supply, that duty is sized by different rules and the fire water reservoir design guide for rural and remote sites is the honest place to begin; nothing on this page is a claim about that use.

The lightest sixteen foot load on this sheet

The plant is Lincoln, Nebraska, and there is no ship-from state field on this sheet at all, so that is everything it says about origin. The shipping load is 102 by 102 by 197 inches at 3,000 pounds, LTL at class 250 with no NMFC number, and the lane is priced to your ZIP with the freight cost estimator; the listed price is before freight. No crane rating, rigging plan, permit or escort requirement is published, and no lifting lug count either, so none is stated and no lift arrangement is described that cannot be sourced. Take it under the base, keep it upright wherever the route allows, and never let a sling sit on the manway. Set it on the finished, cured, level surface in its final position before a single pipe is connected, prove it plumb in two directions while it is empty, then fill it with clean water and hold that 37,530 pound load while you read the manway seal, the base all the way round and the pad beneath it. Drain it, let it dry, open the space between the walls, look in good light and write the date on the shell in paint marker with the part number beside it. Stencil the contents and your stop level on the outside the same week, because nobody is ever going to see the liquid through this wall. And book the second inspection in the calendar before you leave site, since the schedule that never gets written is the one that turns a contained tank back into a single wall one on paper. Walk the base after the first hard rain; a pad that shifts shows it at the edge first.

‌​‌‌‌‌‌‌‌​​​‌‌​‌​​​​‌​‌‌‌‌‌​​​‌​‌​​​​‌​​

Freight and documents

Ships from: Lincoln, NE. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.

Technical drawing (PDF) for Snyder Industries 5620000N46.

See this tank

Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).

Ready to order?

Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.

Adding to cart… The item has been added