Skip to main content

Snyder Industries

Snyder Industries 4650 Gallon HDPE Vertical Liquid Storage Tank with ASTM Certification

$15,770.57
0
(No reviews yet) Write a Review
Adding to cart… The item has been added
SKU:
SII-8210000N45
Availability:
In Stock - Ships from nearest manufacturing plant
Weight:
1,613.00 LBS
Width:
102.00 (in)
Height:
154.00 (in)
Depth:
102.00 (in)
Capacity:
4650 Gallons
Material:
High Density Linear Polyethylene
Color:
White
Diameter:
102"
Lid/Manway:
18" Threaded Vented Manway
Specific Gravity:
1.9
Max Temperature:
120
Certifications:
FDA-compliant resin
Warranty:
3 Year Warranty
Freight Class:
OVS
Manufacturer Part Number:
8210000N45
Manufacturer:
Snyder Industries
Technical Drawing:
https://onesourceplastics.com/content/tech-drawings/sii-8210000n45.pdf
Ship Weight:
1613 lb
Ship Dimensions:
154" L x 102" W x 102" H
Specific Gravity Rating:
1.9 (Max 15.87 lbs/gal)
Lid Size:
18"
Swatch Group:
VST-13666
Specific Gravity Options:
8210000N43 | White Standard 1.5 | /snyder-industries-4650-gallon-hdpe-vertical-liquid-storage-tank-with-astm-certification-sii-8210000n43/

4,650 gallons at 1.9 specific gravity on a 102 inch base

The Snyder 8210000N45 is a white high density linear polyethylene vertical liquid storage tank, 102 inches across and 154 inches tall, holding 4,650 gallons at 1,613 pounds. Its wall is rated for a specific gravity of 1.9, or 73,684 pounds of contents against 38,781 for water, the chemical-grade wall for ferric chloride at strength, concentrated acids and the heavy brines, and the eight and a half foot base takes a tanker load of dense chemical on a pad smaller than the tanker under a thirteen foot roof. The top carries an 18 inch threaded, vented manway, the paperwork carries a 3 year warranty, and the truck carries it oversize.

Spec sheet in hand? Call 866-418-1777 and read us the liquid and the pad; or get freight to your ZIP and add it to your cart above.

Thirty-seven tons of chemical on the small pad

A 1.9 specific gravity wall is sized for a liquid nearly twice as dense as water, and 1,613 pounds of resin is what that takes on this shell, 413 pounds more than the 1.5 wall in the same mold. Rotationally molded polyethylene tanks are sized to ASTM D1998, and the way a tank meets the density it is rated for is in the wall; the HDPE tank wall thickness guide explains the sizing logic and why a wall this tall is inspected from the top, in the headspace. Full, it puts 73,684 pounds on a 102 inch circle at the rating: an engineered slab with nothing but concrete under the whole floor, following the concrete pad sizing guide, inside a berm sized to the tank, with the empty tank strapped against wind and the manway reached from a fixed platform with a rail. The tank sizing calculator works the volume out from feed rate and delivery interval, and the tank sizing guide covers the reserve, which for a dense chemical includes freeboard for thermal expansion.

Grades on the 102 x 154 inch tank, and the sizes beside it

Snyder vertical tanks, 4,600 to 4,900 gallons
PartGallonsDiameter x heightEmpty weight
8210000N45 (this tank, 1.9 SG)4,650102 x 154 in1,613 lb
8210000N42 (XLPE, heavy wall)4,650102 x 154 in1,613 lb
8210000N43 (1.5 SG)4,650102 x 154 in1,200 lb
8210000N464,650102 x 154 in1,200 lb
8210000N40 (XLPE)4,650102 x 154 in1,200 lb
5480000N40 (tall, XLPE)4,90090 x 202 in1,450 lb
7000500N40 (ten foot base, XLPE)4,600120 x 116 in1,450 lb

The N42 is the heavy cross-linked tank at this tank's weight for the densest oxidizers; the N43 is the 1.5 wall, 413 pounds lighter, for coagulants and brines that never approach this density, and the N40 and N46 the lighter cross-linked and linear grades. The 5480000N40 stands 4,900 gallons of cross-linked resin on a 90 inch base at 202 inches, and the 7000500N40 lays 4,600 down to 116 inches on a ten foot base.

Two rows look the same? The difference is the wall; call 866-418-1777 with the liquid and we will say which, or ask for a quote on both.

Where the pipe goes

  • Access: 18 inch threaded, vented manway, 154 inches up; on acid or caustic the vent goes outdoors, the fill goes down a dip tube, and the vent is sized to the tanker pump.
  • Outlet: name the chemical when ordering so the bulkhead fitting matches it; a flanged transition, an expansion joint, and a valve supported off the slab.
  • Service limit: 120 F.

Read the level from the ground through a sender chosen for the chemical, not by climbing; leave the manway closed between fills to hold the vapor, and put the tank in shade if the chemical is light-sensitive. Regulated chemical in a single wall tank means a berm sized to the tank around it. Label it so the fire inspector and the workplace inspector read the same thing. Insulate or drain the outlet valve and the first run of pipe wherever the ground freezes.

Bringing in a load

A tanker's pump moves liquid faster than a manway vent can pass air, so either the vent is sized to the unload rate or the fill comes in through its own top bulkhead with a separate vent line. A fill pipe to the floor keeps caustic or coagulant from free-falling and foaming. A dense liquid heats when water is added to it, so a batch tank is filled with water before the chemical, never after. The first load into a new tank gets watched end to end, eyes on the slab edge and the outlet fitting while the level comes up, and each delivery after it is logged with its date and strength.

The work it does

Ferric and other dense coagulants at a plant with a berm and no floor space, acid feed for pH control, heavy brine at plant scale, dense process chemicals delivered by tanker, and water where the buyer wants the heaviest wall for a long life outdoors, including a fire reserve of the kind the fire-water reservoir design guide describes. One chemical, one tank, one label that both inspectors read the same way.

Freight, in plain terms

At 102 inches across and 154 inches long on the deck the 8210000N45 ships as oversize freight on a flatbed at a lane rate; the freight cost estimator quotes the haul to your ZIP; what is listed is the price before freight. A crane or a forklift with long forks sets 1,613 pounds on the slab. Water-fill it once to the manway, hold it, then drain and dry before the chemical connection is made. Mark the vent and the outlet on the outside of the shell so nobody caps the wrong one in the dark.

​​‌‌‌‌‌‌‌‌‌​​‌​​‌‌‌‌‌‌‌​​​‌‌‌​​‌​​‌​‌‌​​

Freight and documents

Ships from: Marked Tree, AR. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.

Technical drawing (PDF) for Snyder Industries 8210000N45.

See this tank

Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).

Product video. Watch the Snyder Industries 4650 Gallon HDPE Vertical Liquid Storage Tank with ASTM Certification video (70 seconds) with dimensions, fittings and shipping notes.

Ready to order?

Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.

Adding to cart… The item has been added