A 150 gallon natural white crosslinked Snyder tank where seeing the level matters
Snyder part number 1012800N42 is a 150 gallon vertical storage tank molded in crosslinked linear polyethylene, in natural white, 30 inches in diameter and 59 inches tall, weighing 55 lb empty. The white wall lets an operator see the liquid line in ordinary light, so on a hand-charged tank the level is checked in passing rather than with instrumentation; it also admits daylight to the liquid, which is why a chemical that light degrades belongs in the black version. The crosslinked wall is rated to 140 F (60 C) and for liquids up to 1.9 specific gravity. For scale, 150 gallons of water weighs 1,251 lb (150 x 8.34), and at the full 1.9 rating the contents can reach 2,377 lb (150 x 8.34 x 1.9). On top is an 18 inch threaded vented manway. Snyder backs it with a 3 year warranty.
Add it to your cart at the top of this page, get LTL freight to your ZIP, or call 866-418-1777. The listed price is before freight.
Where this tank earns its keep
A white 150 in a crosslinked wall is the tank for a job somebody watches: a metered chemical feed at a small water system, a sanitiser or detergent makeup station in a food or dairy plant, a nutrient tank in a greenhouse where the grower checks the level daily, a laboratory or pilot plant vessel, a shop reservoir for a cleaning solution. Our guide to when crosslinking matters for chemistry duty is where to settle whether the crosslinked wall is required for your chemistry rather than inherited from the last order; check the liquid in the chemical compatibility guide.
The numbers are unforgiving of a lazy install: full, the whole load bears on a 30 inch circle. Level and in full contact is the standard on an existing slab; a new pad follows the concrete pad sizing guide, with containment sized to the tank wherever the liquid is regulated. Empty, 55 lb standing 59 inches on a narrow base is light enough for a door gust or a passing pallet to put over, so strap or bracket it on day one. Check the volume with the tank sizing calculator and the tank sizing guide.
Openings and what to confirm before you buy
- Manway. An 18 inch threaded vented manway on a tank whose footprint is 30 inches, so most of the top is lid, 59 inches up and reachable from the floor. The lid and its gasket are most of what stands between the liquid and the weather, so look at them rather than assume.
- Outlet. The manway is the only opening listed for this tank. Tell us the liquid and the draw-off you want when you order and we will confirm what can be fitted before anything is cut.
- Vent and fill. Run a dip tube through the opening to the floor so the stream does not free-fall and foam; pipe the vent outdoors on anything that fumes and size it to the pump that fills the tank.
- Headspace. Our article on headspace wall thickness identifies the band above the liquid line as the first place a small tank thins; on a white shell the level reads from outside, so there is no excuse for lifting the lid just to look. Snyder's drawing for 1012800N42 is on this page under Technical Drawing.
Sizes nearby
The same shell in other walls: the 150 gallon ASTM XLPE black heavy duty vertical tank (1012800N48) is the identical crosslinked wall in black for a liquid that minds daylight; the 150 gallon black heavy duty vertical tank (1012800C34) and the 150 gallon heavy duty vertical tank (1012800C26) are standard polyethylene. One step down is the 130 gallon heavy duty vertical tank (1007300C26) for a low cabinet; one step up is the 175 gallon heavy duty vertical tank (1008400C26) where the ceiling allows it.
Shipping and receiving
The tank ships LTL at freight class 300 from Snyder's plant in Philippi, WV, 30 by 30 by 59 inches and 55 lb on the pallet. Fifty-five pounds is a hand carry and 30 by 59 inches is real space on a deck, so the bill follows the cube and the distance; put your ZIP into the freight cost estimator before you order. Take it off the liftgate with hands under the base, never by the manway rim. Check the part number against 1012800N42 on the bill of lading and look at the base edge, the threads and the vent while the driver is still there. Then a water fill to the manway, standing where the tank will live, held for the time the hydrostatic test methodology article gives, a look under the base, then drained and dried before the chemical arrives. Mark the working level and the full level on the outside of the wall on day one.
Freight and documents
Ships from: Philippi, WV. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 1012800N42.
See this tank
Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).
Ready to order?
Add it to your cart at the top of this page, get LTL freight to your ZIP, or call 866-418-1777. The listed price is before freight.