550 gallons at 1.9 specific gravity, under four feet tall
The Snyder 8060000C26 is a natural white polyethylene vertical storage tank, 64 inches across and 46 inches tall, holding 550 gallons at 100 pounds. It is the low 550: the same volume as the 48 inch tank in this family laid down to under four feet, for the pad under a mezzanine, a low roof, a trailer or a deck, with the 18 inch threaded, vented manway opened from the ground and the liquid sitting low where a pump wants it. Its wall is rated for a specific gravity of 1.9, or 8,715 pounds of contents against 4,587 for water, so it takes the dense chemicals at strength. A 2 inch polypropylene female NPT bulkhead outlet, a 3 year warranty, and freight at class 400 from Marked Tree, Arkansas or Philippi, West Virginia.
Buying for a site, a fleet or a district? Request a written quote with freight to your ZIP, or add it to your cart above and call 866-418-1777 with any question on the fit.
Floor instead of height
Every site trades floor for height one way or the other; this tank is for the one with floor. At 64 inches across and 46 tall it goes where the 75 inch tank in this family cannot, and its center of gravity is so low that it needs the least strapping of any 550 gallon shape. The 1.9 wall covers concentrated acid, ferric and the heavy brines, and the white wall shows the level through it in daylight. Full at the rating it puts 8,715 pounds on a 64 inch circle, and a rotationally molded floor bears on all of it, so it stands on a slab in full contact per the concrete pad sizing guide, inside a berm when the liquid is regulated; on a trailer, continuous support under the whole floor and a strap over the top. The tank sizing calculator turns feed rate and delivery interval into a volume, and the tank sizing guide covers the reserve to keep the pump wet between deliveries.
The low 550 and the tall one, with the 500 and 710 beside them
| Part | Gallons | Diameter x height | Empty weight |
|---|---|---|---|
| 8060000C26 (this tank, low, 1.9 SG) | 550 | 64 x 46 in | 100 lb |
| 1800400C26 (tall) | 550 | 48 x 75 in | 110 lb |
| 1800000C34 (black, tall) | 550 | 48 x 75 in | 110 lb |
| 1800000N48 (tall) | 550 | 48 x 75 in | 110 lb |
| 1800000N51 (black, tall) | 550 | 48 x 75 in | 110 lb |
| 5780100N42 (XLPE) | 500 | 53 x 77 in | 141 lb |
| 1700200N42 (XLPE, low) | 710 | 60 x 68 in | 185 lb |
The 1800400C26 and its 1800000 siblings are the same 550 gallons stood up on a 48 inch base at 75 inches, in white, black and the other chemical grade, for a site with height and no floor. The 5780100N42 is the 500 gallon cross-linked tank for oxidizers, and the 1700200N42 the 710 in that resin on a 60 inch base at 68 inches, the next low tank up.
Comparing against another maker? Send the competing spec to 866-418-1777 or a quote request and we will show the differences honestly.
Outlet and manway on a low tank
- Outlet: 2 inch polypropylene female NPT bulkhead fitting, at the base; a flexible connector to hard pipe, the valve supported off the pad, and the reducer to the pump's suction at the pump.
- Access: 18 inch threaded, vented manway, 46 inches up, opened from the ground; fill from a tote or a truck through a dip tube, and vent outside on anything that fumes.
- Service limit: 120 F / 48 C.
The liquid column above the outlet is under four feet, so the pump sits as low as the outlet and primes by gravity; a low-level float shuts it off before it draws air. A tank this low can be reached into from the rim for a rinse at a chemical change, which the tall one cannot offer. Keep the manway closed against vapor loss, and label the one chemical the tank holds. Where it freezes, wrap or drain the outlet valve and the first pipe run; the body takes ice from the top down without harm.
Sites with a low ceiling
The chemical supply under a mezzanine at a boiler room, a coagulant tank in the low room at a package plant, a brine tank in a basement, the makeup tank under a plating line's catwalk, and a chemical tank on a trailer. Not a fire tank; the fire-water reservoir design guide works in thousands of gallons and a water wall. Where a reuse system doses treatment chemical between storage stages, the industrial water reuse tank topology article shows where a tank this size sits.
Freight from Marked Tree or Philippi
The 8060000C26 ships from Marked Tree, Arkansas or Philippi, West Virginia, whichever is nearer, as LTL freight at class 400, the class light, bulky tanks take; the freight cost estimator quotes it to your ZIP, and the listed price is before freight. Two people stand 100 pounds; at 64 inches across it goes through a double door or around the building. Fill it with water to the manway once and look at the outlet fitting for a weep, then drain and dry before the chemical goes in. On a trailer, run the same test parked level, then drive it around the block and look again. Save the pallet; a tank that ever has to move again is easier to move on it.
Freight and documents
Ships from: Marked Tree, AR; Philippi, WV. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 8060000C26.
See this tank
Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).
Ready to order?
Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.