A black 70 gallon day tank with a lid the sheet names
For a liquid that light spoils, the 70 gallon tank in the Snyder 1009000 shell is the 1009000C34: black polyethylene, 23 inches across and 41 inches tall, 30 pounds empty, with an 8 inch lid and a 1 inch polypropylene female NPT bulkhead fitting at the base. The sheet rates the wall for a specific gravity of 1.9, which is 1,109 pounds of contents against 584 pounds of water. Molded in Lincoln, Nebraska. A service limit of 120 F / 48 C, a 3 year warranty, and freight at class 250.
Want a second opinion on the size? Call 866-418-1777 with the daily draw and the delivery interval, or price freight to your ZIP and add it to your cart above.
Black in the 1009000 shell, not black in the 1007200
There are two black 70s in the Snyder line and the difference is the shell. The 1007200C34 is black at the same 23 inches across and the same 30 pounds, one inch taller at 42 inches, molded in Merced, California, with no lid field on its sheet; this 1009000C34 is one inch shorter, lists an 8 inch lid, and comes out of Lincoln. Buy this one when the tank will sit east of the Rockies, when the shelf above it is tight to the inch, or when the specification wants a lid opening the sheet names. Against the natural white tank in this same 1009000 shell, which we list separately, the black wall is the pick for hypochlorite and any other liquid that degrades in light; the price is that it hides the level, so a sight tube or a sender is the gauge, and it runs warmer in the sun than white, so it stays out of a south window. Against the cross-linked 1007200N42, the question is only whether the specification asks for cross-linked polyethylene; at 70 gallons and 1.9 the linear wall already carries a dense liquid. Seventy gallons at the rating is 1,109 pounds on a 23 inch circle, nothing for a slab or a steel stand, but the surface must be flat and level so the tank does not rock on its bulkhead fitting, and where the liquid is regulated a tray or berm sized to the tank goes under it. The concrete pad sizing guide is written for tanks that weigh tons; its full-contact rule is the one that matters at 30 pounds. Take the volume to the tank sizing calculator against the dose rate and the refill interval, and the reserve and thermal headspace to the tank sizing guide.
Six small verticals from 65 to 90 gallons
| Part | Gallons | Diameter x height | Empty weight |
|---|---|---|---|
| 1009000C34 (this tank, black, 1.9 SG) | 70 | 23 x 41 in | 30 lb |
| 1007200C34 (black) | 70 | 23 x 42 in | 30 lb |
| 1007200C26 (natural) | 70 | 23 x 42 in | 30 lb |
| 1007200N42 (natural, cross-linked) | 70 | 23 x 42 in | 30 lb |
| 1550000C26 (natural) | 65 | 24 x 46 in | 85 lb |
| 5690100N42 (natural, cross-linked, wide) | 90 | 34 x 41 in | 43 lb |
The 1007200 rows are the other 70 gallon shell in three walls, each rated as its own sheet says. The 1550000C26 is a natural 65 on a 24 inch circle at 46 inches, listed at 85 pounds where the 70s are 30, which the sheet gives and we print. The 5690100N42 is the cross-linked 90 at this tank's own 41 inch height on a 34 inch circle, for a bench with room to the side and none above.
Not sure which one? Tell us the liquid, the site and the ceiling height at 866-418-1777, or request a written quote with freight to your ZIP.
Lid, vent and the dark headspace
- Vent and fill: the 8 inch lid is the fill opening and the vent. A tank this size is filled from a hose, a drum pump or a carboy, and the lid opening passes the air a hand fill displaces; on draw-down the lid must breathe or the pump pulls a vacuum, so it sits loose enough to pass air and tight enough to keep dust and rain out. Put the hose end below the rim so a dense liquid does not splash the wall above the liquid line.
- Headspace: fill to the shoulder. A black wall hides the level and the headspace band, so this is the tank where a light goes in at every fill and the wall above the liquid line gets looked at, not assumed.
- Outlet: 1 inch polypropylene female NPT bulkhead fitting at the base. Name the liquid at order and the fitting, gasket and bolting are matched to it, with a short flexible connector to a valve carried on the stand.
- Service limit: 120 F / 48 C.
Three feet five inches of head over a 1 inch outlet gravity-feeds a metering pump or a day-tank line; set the tank on a stand so the pump inlet sits below the outlet and it runs flooded to the last inch. Because the wall is black, a sight tube off the outlet tee or a small level sender is not optional; an operator cannot see 70 gallons go to ten through this wall. Keep the outlet clear, the chemical's name on the wall, and the lid on. A tank this small freezes solid in one cold night in an unheated room, so it lives indoors or is traced and drained before a hard cold.
Hypochlorite day tanks and dark dose feeds
A hypochlorite day tank beside a metering pump at a small water plant is the job this tank was made for: light degrades the liquid, 70 gallons is a few days of feed, and the black wall keeps it at strength. A dark mix tank for a fertilizer solution at a greenhouse, a process tank in a shop with a south wall, and the small dose tank a reuse system keeps between its storage stages are the others; the industrial water reuse tank topology article shows where a tank of this size sits in that train. It will hold water, but a fire reserve is a different tank bought for a different reason; the fire-water reservoir design guide covers what that reserve looks like, and 70 gallons is not it.
Lincoln, class 250, on a pallet
The 1009000C34 ships from Lincoln, Nebraska as freight at class 250 as the sheet lists it; at 23 inches across and 41 inches tall it rides on a pallet inside the trailer, and the freight cost estimator prices the lane to your ZIP, with the listed price before freight. One person can carry 30 pounds, but two carry it by the body without touching the fitting. Fill it with water to the shoulder once and hold it, watching the base fitting for a weep, then drain and dry it before the chemical goes in. Put a strip of white tape down the black wall at the fill line on day one; it is the cheapest level gauge a black tank will ever have. Chalk the full-water line on the outside after the first fill; it is the level every later reading gets checked against.
Freight and documents
Ships from: Lincoln, NE. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 1009000C34.
See this tank
Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).
Ready to order?
Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.