Ten thousand gallons of black high density wall, rated 1.9
The Snyder 1006600N51 is a 10000 gallon double wall tank, named by the maker as an ASTM Black double wall tank; the name words are the maker's and no standard, listing or approval is claimed from them here. The material field reads high density linear polyethylene and the colour field reads black. The shell is listed at 142 inches long by 142 inches wide by 226 inches tall and 7,400 pounds empty. The sheet publishes one capacity, one set of overall dimensions, one empty weight and one rating for the whole assembly: no separate inner tank figure, no separate outer containment figure, no annulus dimension and no containment percentage appear on it, so this page states none. The wall is rated at a specific gravity of 1.9, and the sheet gives 83,400 pounds for 10,000 gallons of water at 8.34 pounds per gallon with 158,460 pounds of maximum contents. The only opening is an 18 inch threaded vented manway; the outlet field reads "1 Manway / Lid", which names an opening rather than a pipe size, and the inlet field is empty. The service limit is 120 F / 48 C and the warranty is a 3 Year Warranty. The ship mode is LTL at class 250 with no NMFC number, moulded at Lincoln, Nebraska.
Spec sheet in hand? Call 866-418-1777 and read us the liquid and the pad; or get freight to your ZIP and add it to your cart above.
Dense chemical duty where the tank is its own containment
Ten thousand contained gallons at the heavier rating is bought by plants with a bulk delivery programme and a heavy product: municipal water and wastewater treatment, mineral processing and mine site reagent storage, power generation chemistry, pulp and paper, plant-scale metal finishing, fertilizer and agricultural chemical distribution, and large industrial process lines that dose continuously between tankers. The containment is the reason the vessel is specified rather than a plain tank, and what it buys is straightforward: no poured structure to design, drain and maintain around it, and the freedom to stand the tank where the process wants it instead of where a bund could be built. The rating line is the case for this listing in particular. At a specific gravity of 1.9 the sheet carries 158,460 pounds of maximum contents against 83,400 pounds of plain water at 8.34 pounds per gallon, which is wall listed for a product considerably denser than water at the full 10,000 gallons. If your product is heavy, this is the row and the lighter-rated listings in the same shell are not a substitution. Its service limit is 120 F / 48 C, so if the stream also runs warm, tell us and we will point at the sheet that carries the higher figure instead. The colour field reads black, which keeps daylight off the contents and takes away any chance of judging a level through the wall, so a level instrument is a specification item on this tank rather than an option. The site work is a design exercise at this scale. Close to nineteen feet of vessel on a just-under-twelve-foot square puts 83,400 pounds of water, or 158,460 pounds at the published rating, onto that footprint, which is a designed slab on a designed subgrade, poured and cured before the tank is scheduled. Two engineering references belong in the file before the order. A polyethylene wall works hardest at the vapour line rather than under the liquid, which the wall thickness at the vapour saturated headspace guide explains, and where somebody on your side asks how the space between two walls is examined, the cathodic disbondment testing guide for double wall interstitial spaces sets out that methodology and where the polyethylene boundary lies. Size the volume honestly with the Captor double wall freeboard sizing guide, then check usage and drop size in the tank sizing calculator and the tank sizing guide.
Eighty-seven hundred, ten thousand and twelve five on one plan
| Part | Name on the sheet | Gallons | Size and empty weight |
|---|---|---|---|
| 1006600N51 | this tank, ASTM Black, rated 1.9 | 10,000 | 142 x 142 x 226 in, 7,400 lb |
| 1006600N30 | Sulfuric Acid, same listed weight | 10,000 | 142 x 142 x 226 in, 7,400 lb |
| 1006600N40 | ASTM XLPE, lighter listing | 10,000 | 142 x 142 x 226 in, 6,400 lb |
| 1006600N46 | ASTM XLPE Black, lighter listing | 10,000 | 142 x 142 x 226 in, 6,400 lb |
| 1006400N46 | ASTM XLPE Black, same plan, shorter | 8,700 | 142 x 142 x 197 in, 5,000 lb |
| 1031100N30 | Sulfuric Acid, same plan, taller | 12,500 | 142 x 142 x 274 in, 9,500 lb |
Four part numbers share this 226 inch shell and the sheet splits them into two listed weights: this tank and 1006600N30 at 7,400 pounds, 1006600N40 and 1006600N46 at 6,400. The sheet gives the figures and explains neither, so we print them and leave the interpretation with the product you describe to us. Where a drawing or an existing installation already names a part number, order that one and we will confirm the published figures against it. This sheet is unusually generous on the size question because it publishes three capacities on one plan: 8,700 gallons at 197 inches and 5,000 pounds, 10,000 at 226 inches, and 12,500 at 274 inches and 9,500 pounds, all on the identical 142 inch square. Gallons are bought in height and nothing else, so the slab, the approach and the standing room for the delivery machine are common to every row. That makes the decision two measurements and one count: the clear height at the final position with a platform and a fill arrangement allowed for above the manway, any site line or planning cap on the structure, and the number of truck drops a year you want to sign for. Fewer, larger drops usually improve the cost per truck drop, so where the height is genuinely available the taller row tends to win on running cost rather than on purchase price.
Two rows look the same? The difference is the wall; call 866-418-1777 with the liquid and we will say which, or ask for a quote on both.
Suction, prime and low level on a ten thousand
- The suction path: this sheet publishes one opening and no outlet dimension, so the pump arrangement is engineered with us rather than assumed from the listing. The head at the base of a 226 inch column sets the pump, the valve and every joint below the liquid line, and a heavy product at the 1.9 rating makes that number larger than water would.
- Prime: a pump serving a vessel this tall begins a draw with plenty of head and ends it with very little, so specify for the end of the draw and not the beginning. Keep the suction run as short and as rigid as the layout allows.
- Low level protection: set the stop level, protect it with a cut-out chosen alongside the pump, and do not rely on an operator's eye. The wall is black and nothing can be read through it.
- The outlet field: it reads "1 Manway / Lid" with the inlet field empty, which names an opening and not a pipe size. No outlet dimension, thread, bulkhead, flange or valve is published on this sheet, so none is claimed here. Give us the line size, the valve and the pump arrangement and we will confirm what this part number carries.
- The manway: 18 inches, threaded and vented, and the only opening the sheet publishes. At 226 inches it needs a fixed ladder or platform, a fall protection arrangement, and a fill connection brought to ground level so nobody climbs to take a delivery.
- The vent: part of the manway. On a bulk fill into 10,000 gallons the air moving through that path is the wall's only protection, and the same is true in reverse on a hard pump-down. Keep it clear and never restrict it.
- Structure: the sheet lists 8 lifting lugs, ladder lugs and 2 flange lines on this shell.
- The space between the walls: no monitoring port, gauge or alarm is published on this sheet, so that arrangement is specified separately and written into a procedure.
- Limits: 120 F / 48 C, a specific gravity rating of 1.9, and a 3 Year Warranty.
Name the product and its strength at order time; at this volume every wetted part is selected against the chemistry, and the fitting is the one route out of a tank that otherwise has two walls around it.
Municipal treatment and mineral processing storage
Ten thousand gallons at the heavier rating serves the plants where the product is dense and the delivery is bulk: municipal water and wastewater treatment, mining and mineral processing reagent storage, power station and cooling water chemistry, pulp and paper, plant-scale metal finishing, fertilizer and agricultural chemical distribution, and industrial process lines that dose steadily between tankers. At this size the tank sets the rhythm of the site, so agree the receiving procedure when you buy it rather than on the first delivery: where the driver connects, who watches the fill, what the stop level is, who signs it off, and what happens if the vent is obstructed. Deliveries into a vessel that was fuller than anybody thought are where nearly all the bad days on bulk storage begin. Where private fire water storage is the real question behind a vessel this size, the fire water reservoir design guide for rural and remote sites sets out how that duty is sized; nothing on this page is a claim about it. And build the inspection of the space between the walls into the maintenance system on day one, with dates recorded, because the second barrier is worth precisely what your evidence says about it and no more.
Seventy-four hundred pounds, Lincoln, one lift
Lincoln, Nebraska is the only plant this sheet names and no ship-from state field appears on it, so the plant is printed and nothing more about the lane is claimed. The ship mode is LTL at class 250 with no NMFC number, and the load is 142 by 142 by 226 inches at 7,400 pounds. Price the lane to your ZIP with the freight cost estimator; the listed price is before freight. No crane capacity, rigging plan, permit or escort detail is published on this sheet and none is invented here; the sheet does publish 8 lifting lugs, and the lift is planned by your rigger against the machine that can reach the position. Tell us what can get into the yard and where the tank has to stand, early enough to matter. A vessel just under twelve feet across and close to nineteen feet tall needs a clear approach, room for the machine to stand, and a cured, level pad waiting for it. Lift by the arrangement the rigger specifies, never by the manway. Set it plumb, prove it in two directions, and confirm the whole 142 inch footprint bears evenly before anything is connected. Fill with clean water, hold that 83,400 pound load, and walk the base line, the manway seal and the pad in good light while it is loaded. Drain it, let it dry, open the space between the walls, record what you saw and the date, and photograph the base from four sides. Keep the first fill record and the part number with the plant file, because the next person to specify against this tank will not have the paperwork that came with it. Mark the vent and the outlet on the outside of the shell so nobody caps the wrong one in the dark.
Freight and documents
Ships from: Lincoln, NE. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 1006600N51.
See this tank
Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).
Ready to order?
Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.