A 5,000 gallon heavy duty vertical tank in natural white that fits under a ten foot roof
Snyder Industries part number 7000500C26 is a natural white polyethylene vertical storage tank holding 5,000 gallons, 120 inches in diameter and 116 inches tall, weighing 650 lb empty. It is the heavy duty version of this shell, rated for liquids up to 1.9 specific gravity, which is the wall for dense coagulants, acids and brines; water and fertilizer are well inside it. It comes with a 3 inch polypropylene female NPT bulkhead fitting as the outlet and an 18 inch threaded vented manway on top. Snyder rates it for service to 120 F (48 C) and backs it with a 3 year warranty. The white wall shows the level through it. It is moulded at Chowchilla, California.
Ready to order? Add it to your cart at the top of this page, get LTL freight to your ZIP, or call 866-418-1777. The listed price is before freight.
One tanker, low ceiling, heavy liquid
A water plant with a chemical room built under a standard roof, or an ag chemical yard that takes one tanker of acid at a time, buys this tank because the tall 5,000s do not fit the building. At 116 inches it stands under a ten foot roof line, the manway is reached from a step rather than a platform, and at 650 lb it is set with a forklift rather than a crane. A low, wide tank also has the lowest centre of gravity in its class and wants the least restraint, though it still gets strapped before the first fill. The trade is floor: it needs a 120 inch circle of flat, continuous support. Full of water it weighs 5,000 x 8.34 = 41,700 lb plus the tank, and a liquid at the 1.9 rating almost twice that, so the slab follows our concrete pad sizing guide and sits inside a berm where the liquid is regulated. The tank sizing calculator checks whether 5,000 gallons covers the draw between deliveries; the tank sizing guide covers the reserve and the headspace a dense chemical needs as it warms.
What goes in it
Check the liquid against polyethylene in our chemical compatibility guide before you order and tell us what it is so the outlet fitting is matched to it. White runs cooler in the sun than black, which suits a chemical that gases off when warm, but it passes some light, so a liquid that breaks down in light belongs in the black version of this shell. Water is well inside the rating; the fire water reservoir design guide covers a polyethylene tank's place in a fire reserve, and the industrial water reuse tank topology article shows the stage where a tank this size sits in a reuse system.
Openings and fittings
- Outlet. A 3 inch polypropylene female NPT bulkhead fitting low in the wall. A pump at pad level sees less than ten feet of head at full and a few inches at empty, so set the low level float a little higher than you would on a tall tank, keep the suction line short and straight, and put the strainer where it can be cleaned without draining the run. Support the valve and the first pipe run off the pad and trace or insulate them where winters freeze.
- Manway. An 18 inch threaded vented manway on top, 116 inches up, reached from a step. Fill through a dip tube to the floor, pipe the vent outside on anything that fumes, and size the vent for the truck's pump.
- Drawing. Snyder's drawing, linked under Technical Drawing on this page, gives the fitting positions.
Sizes nearby
Snyder's taller 5,000 gallon tanks sit on a narrower base: the 5000 gallon black heavy duty vertical tank in this wall, the 5000 gallon black vertical tank in the standard wall, and the 5000 gallon ASTM XLPE vertical tank in cross-linked polyethylene. Slimmer still is the 4900 gallon ASTM XLPE vertical tank. For water only, the 5100 gallon vertical liquid storage tank in white. Ask us for the standard wall on this low shell if the liquid does not need the 1.9 rating.
Shipping and receiving
The tank ships from Chowchilla, California at freight class 400, 120 by 120 by 116 inches on a pallet. At 120 inches across it is wider than ordinary LTL freight, so the freight cost estimator will send you to the phone for this size; 866-418-1777 prices the lane. The listed price is before freight. A forklift with long forks sets 650 lb on the pad with straps under the body, never through the manway. Check the part number 7000500C26 against the bill of lading, look over the floor edge and the outlet fitting, fill it with water the first time and hold it a day, then drain and dry it before the chemical arrives. The vent screen is the cheapest part on the tank and the one that saves it; look at it every time the manway opens.
Questions before you order? Call 866-418-1777.
Freight and documents
Ships from: Chowchilla, CA. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 7000500C26.
See this tank
Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).
Ready to order?
Add it to your cart at the top of this page, get LTL freight to your ZIP, or call 866-418-1777. The listed price is before freight.