Skip to main content

Snyder Industries

Snyder Industries 4900 Gallon ASTM XLPE Vertical Storage Tank

$19,169.00
0
(No reviews yet) Write a Review
Adding to cart… The item has been added
SKU:
SII-5480000N40
Availability:
In Stock - Ships from nearest manufacturing plant
Weight:
1,450.00 LBS
Width:
90.00 (in)
Height:
202.00 (in)
Depth:
90.00 (in)
Capacity:
4900 Gallons
Material:
Crosslinked Linear Polyethylene
Color:
Natural White
Diameter:
90"
Lid/Manway:
18" Threaded Vented Manway
Specific Gravity:
1.5
Max Temperature:
140° F / 60° C
Certifications:
FDA-compliant resin, NSF 61
Warranty:
3 Year Warranty
Freight Class:
300
Manufacturer Part Number:
5480000N40
Manufacturer:
Snyder Industries
Technical Drawing:
https://onesourceplastics.com/content/tech-drawings/5480000n40.pdf
Ship Weight:
1450 lb
Ship Dimensions:
90" L x 90" W x 202" H
Lid Size:
18" Threaded Vented Manway
Swatch Group:
VST-15383
Color Options:
5480000N46 | Black Standard 1.5 | /snyder-industries-4900-gallon-astm-xlpe-black-vertical-storage-tank-5480000n46/
Specific Gravity Options:
5480000N48 | Black Heavy Duty 1.9 | /snyder-industries-4900-gallon-astm-xlpe-black-heavy-duty-vertical-storage-tank-5480000n48/

4,900 gallons rated 1.5, 1,450 pounds on the forklift

Of the four walls molded in this shell, the Snyder 5480000N40 is the lighter one at 1,450 pounds empty: 4,900 gallons in a 90 inch circle standing 202 inches tall, natural white crosslinked polyethylene from Lincoln, Nebraska. Its sheet rates the wall for a specific gravity of 1.5, which it reads as 61,299 pounds of maximum contents, against 40,866 pounds for plain water at 8.34 pounds per gallon. It carries an 18 inch threaded, vented manway, eight lifting lugs, four tiedown lugs, ladder lugs and three flange lines, gives the outlet field as 14, a service limit of 140 F / 60 C, a 3 year warranty, and freight at class 300.

Need it before the next delivery? Call 866-418-1777 for the ship date, or get freight to your ZIP and add it to your cart above now.

A tall shell on a small pad, and what the concrete has to do

Work out the pounds per square foot before anything else, because this shape concentrates them. The floor is a 90 inch circle, seven and a half feet across, and it carries 40,866 pounds of water or as much as 61,299 pounds of contents at the rating this sheet gives; a molded floor sits on every square inch of the concrete and follows a low quarter rather than bridging it, so the slab is engineered, level and in full contact under the entire base, per the concrete pad sizing guide. Next comes the roof line, since 202 inches of shell plus the lid, the fill line and the vent needs a tall bay or open sky and no variation of this tank fits under low steel. Then the wind, which is the reason the four tiedown lugs exist: at 1,450 pounds empty this shell is light for its height, and the day the yard gusts is the day the tank is down to a heel, so the bands go to anchors cast in the slab before the first fill, get tensioned while it is empty, and get looked at after the first hot week and again in the fall. Keep a hard surface under the connection instead of gravel, leave a walking gap on at least three sides so the base can be inspected with a light, and put a berm sized to the tank around it wherever the liquid is regulated. Run 4,900 gallons against your draw in the tank sizing calculator, and take the reserve and the thermal freeboard from the tank sizing guide.

Four walls on the 202 inch shell, and two neighbours

Snyder vertical tanks, 4,650 to 5,000 gallons
PartGallonsDiameter x heightEmpty weight
5480000N40 (this tank, 1.5 SG)4,90090 x 202 in1,450 lb
5480000N46 (black, same weight)4,90090 x 202 in1,450 lb
5480000N42 (heavy duty)4,90090 x 202 in2,000 lb
5480000N48 (black, heavy duty)4,90090 x 202 in2,000 lb
8210000N40 (wider, lower)4,650102 x 154 in1,200 lb
1002100C34 (black, wider, larger)5,000102 x 154 in950 lb

Buy this one rather than the 5480000N42 or the 5480000N48 when the liquid weighs about what water weighs, because those two are listed at 2,000 pounds empty and the wall they are paying for is wall a light liquid will never load; at 1.5 this sheet already covers process water, rinse water, wash water and the lighter solutions, and the lighter shell rides at class 300 and is easier to stand up on the pad. The 5480000N46 is the same 1,450 pounds in black, rated as its own sheet says, so between it and this row the question is colour and weathering rather than duty. Off this footprint the trade is height for floor: the 8210000N40 holds 4,650 gallons on a 102 inch circle and stands only 154 inches for a lower building, and the 1002100C34 gets 5,000 gallons onto that shorter footprint in black at 950 pounds. This is the tank for a narrow pad, a tall space, and a liquid at water weight.

Need a different size? Every tank in the table is in stock programs; ask for a quote on the one that fits, or call 866-418-1777.

A 14 in the outlet field with sixteen feet of column above it

  • Outlet: the sheet lists the outlet as 14, with no fitting diameter, material, thread or gasket alongside it, so it is not a pipe size and is not printed as one here. The draw-off is specified at order: name the liquid and the pipe size and the bulkhead, gasket and bolting are matched to them.
  • Access: 18 inch threaded, vented manway at the top of 202 inches of shell; the sheet lists ladder lugs, and anyone opening that lid is working at height and tied off.
  • Structure: three flange lines, eight lifting lugs and four tiedown lugs, as listed.
  • Service limit: 140 F / 60 C. Warranty: 3 year.

The thing to design around here is the column of liquid standing over that connection, because it is generous and it cuts both ways. In your favour, a transfer pump mounted below the fitting will hold a prime far into the working range and the last inches will leave the tank rather than sit there; against you, the fitting and the first valve see more static pressure than they would on a squat tank, so the valve goes on its own support off the pad and a flexible connector, not a rigid spool, ties the bulkhead to hard pipe. Set the bulkhead low enough that the tank genuinely empties, keep the suction run short and straight, and fit a low-level float so the pump never draws air. Fill down a dip tube to the floor to keep foam and static down, size the vent to the delivery pump because a truck moves air faster than a small vent passes it, and put the level sender where it can be read at grade instead of climbed for. Latch the lid between fills, name the one liquid on the wall, light the wall above the working level at every opening, and in freezing country protect the valve and the first pipe run.

Municipal dosing and process water in a narrow footprint

This is the tank for a plant with 4,900 gallons to store and nowhere to spread out: a small water or wastewater system fitting a dosing solution into a chemical yard that is already laid out, a shop or truck wash banking rinse and wash water, a food or beverage plant with a cleaning solution in a tall bay, a co-op with a fertilizer solution, and any manufacturer replacing a row of totes with one vessel. A fire reserve is a separate exercise with its own sizing discipline and belongs in a water-duty vessel rather than being estimated from gallons, which the fire-water reservoir design guide sets out. Where rinse water, rainwater or condensate is being collected and put back to work, the industrial water reuse tank topology article places a tank of this size in the train and says what it should not be asked to hold.

Class 300 out of Nebraska, sixteen feet on the deck

The 5480000N40 ships from Lincoln, Nebraska as freight at class 300 as the sheet lists it, and at 202 inches long it rides as a permitted load, so the gate, the turn and the route matter as much as the pad. Get the number for your ZIP from the freight cost estimator, and the listed price is before freight. Stand 1,450 pounds up on the eight lifting lugs the sheet lists, with straps to the lugs or under the body and never a hook through the manway, land it on the anchors already set, and tighten the tie-downs before the crew leaves. Then fill with water to the manway, hold it a shift, and read the base, the pad edge and the fitting you specified before the product arrives. Once it is full and holding, leave it alone for a day before the plumbing goes on, because a settled tank is a quiet one and a pipe run made up to a tank that is still moving will be made up twice. Keep the first delivery's paperwork with the tank; strength and date on day one is the baseline for every batch after.

‌​‌‌​‌‌​​‌‌‌‌​‌‌‌​​​‌​‌​‌​‌​​‌​‌‌​​​‌‌​​

Freight and documents

Ships from: Lincoln, NE. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.

Technical drawing (PDF) for Snyder Industries 5480000N40.

See this tank

Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).

Ready to order?

Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.

Adding to cart… The item has been added