The black cross-linked 2,000 at 1.5: the tank that fits under a low eave
Seven feet four inches. That is the height of the Snyder 5050000N46, and it is the reason a plant with a low chemical room buys 2,000 gallons in this shell rather than a taller one: 90 inches across, 88 inches tall, 340 pounds empty, with the 18 inch threaded, vented manway reached from a step. It is black cross-linked polyethylene rated for a specific gravity of 1.5 on its sheet, which is 25,020 pounds of contents against 16,680 pounds of water, the wall for hypochlorite, fertilizer solutions and the everyday process chemicals. A service limit of 140 F / 60 C, a 3 year warranty, and freight at class 400 from Lincoln, Nebraska or Philippi, West Virginia.
Talk to a person first? 866-418-1777 reaches a tank specialist, not a call center; or see freight to your ZIP and add the 2000 gallon tank to your cart above.
Pick the N46 for the resin, not the weight
Four tanks share this shell, and three of them weigh 340 pounds; this is one of the three. What sets it apart from the C34 and the C37-BLACK beside it is not wall thickness but resin: cross-linked polyethylene, the wall a specification calls for when it wants resistance to stress cracking and impact beyond what a linear wall gives at the same weight. Each of those neighbors is rated as its own sheet says. The heavy-duty cross-linked tank in the same shell weighs more and is rated as its own sheet says, for liquids nearly twice the density of water; that is the tank for concentrated acid and the wrong tank to pay for when the liquid is hypochlorite. So the choice runs in two steps: cross-linked or not, then 1.5 or the heavy wall. Full at the rating this tank puts 25,020 pounds on a 90 inch circle, so the pad is engineered per the concrete pad sizing guide, level and in full contact, inside a berm sized to the tank where the liquid is regulated. Seven feet of tank on a seven and a half foot base is the steadiest shape in the family, but it is strapped before the first fill anyway. Black polyethylene absorbs the ultraviolet that ages a white wall and passes no light to the liquid; it runs warmer in the sun, so shade it if the chemical must stay cool, and it hides the level, so a sender read at the ground is the gauge. Whether 2,000 gallons covers the draw between deliveries is a question for the tank sizing calculator; the reserve and the warm-weather headspace are in the tank sizing guide.
Four tanks in the 90 x 88 inch shell, and the two beside them
| Part | Gallons | Diameter x height | Empty weight |
|---|---|---|---|
| 5050000N46 (this tank, black, 1.5 SG) | 2,000 | 90 x 88 in | 340 lb |
| 5050000C34 (black) | 2,000 | 90 x 88 in | 340 lb |
| 5050000C37-BLACK (black) | 2,000 | 90 x 88 in | 340 lb |
| 5050000C26 | 2,000 | 90 x 88 in | 340 lb |
| 1780200N40 (slim, tall) | 1,900 | 72 x 119 in | 445 lb |
| 5090000C26 (tall) | 2,500 | 90 x 107 in | 450 lb |
The C34 and C37-BLACK are the other black tanks in the shell and the C26 the natural one, all at this weight, each rated as its own sheet says; the sheet lists the heavy-duty cross-linked tank in this shell as its own product at a heavier weight, and we carry it separately. The 1780200N40 turns 1,900 gallons on its side, so to speak: a six foot circle at 119 inches for a site with an alley and a high roof. The 5090000C26 keeps this tank's 90 inch base and adds nineteen inches of height for 2,500 gallons.
Neighboring size a better fit? Every row links to its own page; freight to your ZIP is quoted on each, or call 866-418-1777.
Breathing room: the vent, the fill and the shoulder
- Vent and fill: an 18 inch threaded, vented manway at seven feet four inches, opened from a step. The lid vent breathes a gravity fill and a small transfer pump; a tanker pump moves air out faster than the lid vent passes it, so on pumped deliveries the vent is sized to the pump or the manway is opened for the fill with someone standing at it. Screen the vent, and run it outdoors on a liquid that fumes.
- Headspace: fill to the shoulder. Hypochlorite gives off gas as it ages and expands as it warms, and the headspace takes both; the band of wall above the liquid line gets a light at every opening.
- Outlet: the outlet field on the sheet reads 12, and we print it as the sheet gives it. Tell us the liquid at order and the bulkhead fitting, gasket and bolting are matched to it, with a flexible connector to hard pipe and the first valve supported off the pad.
- Service limit: 140 F / 60 C.
Seven feet of head is modest, so the pump on this tank sits below the outlet where gravity primes it, with a low-level float so it never draws air. Because the lid is within reach, this is a tank people open too often; keep it shut between deliveries so vapor stays in and rain stays out, name the one chemical on the wall, and look at the vent screen when the lid comes off. Where it freezes, the valve and the first pipe run get trace heat or insulation; the body ices from the top down without harm.
Comparing the 2,000s and where this one wins
The 2,000 gallon vertical tank comparison sets this shell beside the other makers' 2,000s; the cross-linked wall at 1.5 in black is what this listing brings to that table. It goes to a small water or wastewater plant for hypochlorite, a co-op for a fertilizer solution under a lean-to, and a shop with a process chemical on a pad beside the building. Where site rules ask for a second wall, the Captor double wall freeboard guide works through what a contained tank gives up in usable volume at this size. It will hold water, but a fire reserve wants a tank bought for water; the fire-water reservoir design guide explains why.
Class 400 from Nebraska or West Virginia, 340 pounds on the forks
The 5050000N46 ships from Lincoln, Nebraska or Philippi, West Virginia as freight at class 400 as the sheet lists it; at 90 inches across and 88 inches long on the deck it rides on a flatbed, and the freight cost estimator prices the lane to your ZIP, with the listed price before freight. A forklift with long forks sets 340 pounds on the pad with the forks under the body, never through the manway, and the straps go on the same day. Fill it with water to the shoulder once and hold it, watching the pad edge and the base fitting for a weep, then drain and dry before the chemical arrives. Once it is full and holding, leave it alone for a day before the plumbing goes on; a settled tank is a quiet one.
Freight and documents
Ships from: Lincoln, NE; Philippi, WV. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 5050000N46.
See this tank
Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).
Ready to order?
Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.