The wide 2,000: eight feet across, seven feet tall, black, molded in Chowchilla
The Snyder 5050300C37-BLACK is a black polyethylene vertical storage tank, 96 inches across and 84 inches tall, holding 2,000 gallons at 420 pounds. Snyder builds the same 2,000 gallons on a 90 inch base at 88 inches; this is the wider, lower molding out of Chowchilla, California, the one that fits under a seven foot eave and puts the 18 inch threaded, vented manway where a person on a step can open it. The wall is rated for a specific gravity of 1.5, or 25,020 pounds of contents against 16,680 for water, so it holds water, brine and the lighter treatment chemicals at strength, and the black resin keeps light off all of it. A 2 inch polypropylene female NPT bulkhead outlet, a 3 year warranty, and freight at class 400.
Ready to price it? The listed price is before freight; quote freight to your ZIP in a few seconds, then add to cart above or call 866-418-1777.
Why the 96 inch base instead of the 90
Four inches of height is the answer. The 5050000 tanks stand 88 inches on a 90 inch base; this one stands 84 on 96, and under a lean-to or a low chemical shed those four inches are the difference between a tank that goes in and a tank that does not. The wider base also lowers the center of gravity, so the empty tank needs less against wind than the taller shell, though it still gets strapped before the first fill. The price is floor: an eight foot circle instead of seven and a half. Full at the rating it puts 25,020 pounds on that circle, and because a rotationally molded floor bears on the whole pad, the pad carries it: a slab in full contact or a compacted, screeded gravel base sized per the concrete pad sizing guide, inside a berm when the liquid is regulated. Black polyethylene absorbs the ultraviolet that ages a white wall and passes no light to the liquid, so hypochlorite and other light-sensitive chemicals last longer in it, and water in it stays clear of algae; it runs warmer in the sun than white, which argues for shade if the chemical must stay cool. The Snyder versus Norwesco versus Chem-Tainer 2,000 gallon comparison sets this shell beside the other makers' 2,000s, and the tank sizing calculator and tank sizing guide settle whether 2,000 gallons covers the draw between deliveries.
Two shells for 2,000 gallons, and the 1,900 and 2,500 beside them
| Part | Gallons | Diameter x height | Empty weight |
|---|---|---|---|
| 5050300C37-BLACK (this tank, black, wide) | 2,000 | 96 x 84 in | 420 lb |
| 5050000C37-BLACK (black) | 2,000 | 90 x 88 in | 340 lb |
| 5050000C34 (black, heavier wall) | 2,000 | 90 x 88 in | 340 lb |
| 5050000C26 (white, heavier wall) | 2,000 | 90 x 88 in | 340 lb |
| 1780200N40 (slim) | 1,900 | 72 x 119 in | 445 lb |
| 5090000C26 (white) | 2,500 | 90 x 107 in | 450 lb |
The 5050000C37-BLACK is this tank's rating in the narrower shell, the C34 the black tank with the heavier wall in that shell, and the C26 the white one with the heavier wall, each rated as its own sheet says. This molding is listed at 420 pounds against 340 for the 90 inch tanks; the sheet gives both and we print what it says. The 1780200N40 stands 1,900 gallons on a six foot base at nearly ten feet, the shape for a site with height and no floor, and the 5090000C26 stands 2,500 gallons on the 90 inch base at 107 inches.
Want us to check the fit? Send the site dimensions to 866-418-1777 or through a written quote request and we will confirm the tank, the pad and the freight.
Vent first, then the outlet
- Vent: the 18 inch manway is threaded and vented, and on a tank filled from a truck the vent is the fitting that matters most. A delivery pump pushes air out as fast as it pushes liquid in, and a vent that cannot pass that air lets the tank pressurize; a pump drawing down faster than the vent breathes in lets it pull a vacuum. Size the vent to the fastest pump that will ever touch the tank, screen it, and on a fuming chemical run it outdoors.
- Headspace: fill to the shoulder, not the manway. A dense chemical grows as it warms in a black wall in the sun, and the headspace is where it goes.
- Outlet: 2 inch polypropylene female NPT bulkhead fitting, at the base; tell us the liquid when ordering and the fitting is matched to it, with a flexible connector to hard pipe and the valve supported off the pad.
- Access: 18 inch threaded, vented manway, 84 inches up, opened from a step.
- Service limit: 120 F / 48 C.
Seven feet of liquid above a 2 inch outlet is a flooded suction for a chemical feed pump to the last few inches; mount the pump below the outlet so gravity primes it, and a low-level float shuts it down before it draws air. A black wall shows no level, so a sender read at the ground is the gauge. Where it freezes, the outlet valve and the first pipe run are what crack; wrap or trace them and let the body ice from the top down, which it takes without harm.
Low sheds, light-sensitive liquids
Hypochlorite or a coagulant at a small water plant with a low chemical room, brine at a food plant, liquid fertilizer at a co-op, and a black water tank under a low eave where algae is the enemy. As a fire reserve it holds water well within its rating, and the fire-water reservoir design guide covers what the outlet and the draft connection need to be for that job. Where a reuse system stores treatment chemical or a quality-banded water stream between stages, the industrial water reuse tank topology article shows where a 2,000 gallon black tank sits.
From Chowchilla, and the first fill
The 5050300C37-BLACK ships from Chowchilla, California as LTL freight at class 400, the class light, bulky tanks take; the freight cost estimator quotes the lane to your ZIP, and the listed price is before freight. At 96 inches across it goes around the building, not through it, and a forklift with long forks or four people set 420 pounds on the pad; strap it before the truck leaves. Fill it with water to the shoulder once and hold it a day, watching the pad edge for settlement and the outlet fitting for a weep, then drain and dry it before any chemical goes in. Write the chemical on the wall in paint marker the day it lands; a black tank tells nobody what is inside it. A photo of the tank on its pad, full, on day one is worth keeping; it is the baseline every later inspection is compared against.
Freight and documents
Ships from: Chowchilla, CA. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 5050300C37-BLACK.
See this tank
Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).
Ready to order?
Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.