8,000 gallons at 1.5, four hundred pounds lighter to set
Same shell, lighter wall: the Snyder 5300600N46 holds 8,000 gallons in a black cross-linked polyethylene body 120 inches across and 186 inches tall, and weighs 1,900 pounds empty. The sheet rates it for a specific gravity of 1.5, which reads as 100,080 pounds of maximum contents against 66,720 pounds for plain water at 8.34 pounds per gallon. An 18 inch threaded, vented manway sits on top; the outlet field reads 1 Manway / Lid, so the draw-off is specified at order. Eight lifting lugs, ladder lugs and two flange lines are molded in. Class 300 freight from Chowchilla, California, a 3 year warranty, and 140 F / 60 C as the service limit.
Is this the right 8000 gallon tank? Call 866-418-1777 with the liquid, the site and the ceiling height, or get freight to your ZIP and add it to your cart above.
The duty: light chemistry by the tanker load
Who buys this one: a treatment plant dosing hypochlorite, a co-op holding a liquid fertilizer solution that is no heavier than the 1.5 rating on this sheet, a food or beverage plant with a caustic wash system, a landfill or industrial site with a process water stream that has to be stored dark. What they share is volume, not density. The delivery is a tanker into one vessel, the 100,080 pounds the rating allows is more than the load will ever weigh, and paying for the heavy-duty wall in the same shell would buy nothing but four hundred extra pounds on the crane pick. Plain water in this shell is 66,720 pounds, all of it standing on a 120 inch circle, because a molded floor bears across its whole floor: engineer the slab to the concrete pad sizing guide, level and in full contact, with a berm around it where the liquid is regulated. Fifteen and a half feet of empty tank catches wind, so it gets banded to structure or to slab anchors the day it lands, and the bands get a look after the first storm. Black polyethylene keeps light off the liquid, which is the point for hypochlorite, and it takes the ultraviolet that ages a white shell; it also hides the level, so the gauge is a sender. Check 8,000 gallons against your real draw with the tank sizing calculator, and take the reserve and the thermal freeboard from the tank sizing guide.
The 8,000 gallon shell, wall by wall
| Part | Gallons | Diameter x height | Empty weight |
|---|---|---|---|
| 5300600N46 (this tank, black, rated 1.5) | 8,000 | 120 x 186 in | 1,900 lb |
| 5300600N40 (black) | 8,000 | 120 x 186 in | 1,900 lb |
| 5300600N42 (black, heavier wall) | 8,000 | 120 x 186 in | 2,300 lb |
| 5300600N48 (black, heavier wall) | 8,000 | 120 x 186 in | 2,300 lb |
| 7370000N40 (lower roof line) | 7,900 | 120 x 177 in | 2,700 lb |
| 7400000N40 (more volume, more height) | 8,500 | 120 x 186 in | 2,400 lb |
The choice inside this shell is a rating choice, and it is the one decision that cannot be changed after the tank is on the pad. This tank and the 5300600N40 are the 1,900 pound walls, each rated as its own sheet says; the 5300600N42 and 5300600N48 are the 2,300 pound heavy-duty walls for liquids the lighter rating does not cover. Nothing else moves: same 8,000 gallons, same 120 inch base, same 186 inch height, same 18 inch top. Outside the shell, the 7370000N40 trades a hundred gallons for a shorter body when a roof or a pipe rack is in the way, and the 7400000N40 is the step up in volume on the same footprint.
Comparing across brands too? Call 866-418-1777; we carry Norwesco, Snyder, Chem-Tainer, Enduraplas and Bushman and will say which one fits, or price the freight first.
Suction, prime and the float on a lighter wall
- Suction: this sheet's outlet field reads 1 Manway / Lid and lists no bottom fitting size. Name the liquid and the flow at order and the bulkhead, the gasket and the bolting are matched to it, with a flexible connector to hard pipe and the first valve carried on a stand off the pad.
- Prime: with 186 inches of liquid above it, a pump set below the outlet runs flooded far into the drawdown. That is worth designing for on a light liquid too, because a self-priming pump that never has to self-prime lasts longer than one that does it twice a shift.
- Low level: put a low-level cutout on the tank rather than trusting the operator, and set it where the sender still reads reliably instead of at the last inch.
- Access: 18 inch threaded, vented manway, 186 inches up, with ladder lugs molded in. Fill down a dip tube to the floor so a fuming liquid is not splashed into the headspace, and run the vent outdoors, sized to the delivery pump.
- Service limit: 140 F / 60 C.
The vent is the fitting people get wrong on a tank that takes deliveries. A tanker pump can move air out of 8,000 gallons of headspace faster than an undersized vent will pass it, and the shell is not a pressure vessel; size the vent to the pump, not to the pipe that was already there. Two flange lines are molded in for side piping, and every penetration gets made properly, because a leak found at 66,720 pounds of water is a much better day than one found later. Between deliveries the manway stays closed, the liquid is named in paint on the wall, and the wall above the liquid line gets looked at with a light, since that band sees vapor and sun and no liquid at all.
Where the light 8,000 earns its pad
Hypochlorite at a treatment plant that takes full tankers, a liquid fertilizer solution at a co-op inside the rating, caustic for a wash system, and stored process or reclaimed water on an industrial site. That last one has a topology of its own: where reclaimed and harvested streams are banded by quality and stored between treatment stages, the industrial water reuse tank topology article shows where a vessel of this size belongs in the train. A dedicated fire reserve is a different job with its own sizing and freeze rules, covered in the fire water reservoir design guide, and worth reading before a storage tank gets volunteered for it.
What the freight desk needs for the 1,900 pound 8,000
Chowchilla, California is the plant on this sheet, and the freight is class 300 as listed, with the NMFC field blank. Give the desk three things: the 120 inch diameter, the 186 inch height, and whether the delivery site has equipment to unload, because at 1,900 pounds and this size it is a flatbed with a permit-shaped load, not a dock delivery. The freight cost estimator prices your ZIP, and the listed price is before freight. Set it with slings under the body using the eight lifting lugs, hydrostatic test it with water to the manway and hold it while someone watches the base, then drain and dry before the chemical arrives. Write the fill date on the manway collar with a paint marker; it is the first thing anyone asks about a tank and the last thing anyone remembers. Write the fill date on the manway with a paint marker; it answers the first question anyone asks about a tank.
Freight and documents
Ships from: Chowchilla, CA. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 5300600N46.
See this tank
Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).
Ready to order?
Add it to your cart at the top of this page, get LTL freight to your ZIP, or call 866-418-1777. The listed price is before freight.