1,500 gallons at 1.9 specific gravity, six feet tall on an 86 inch base
The Snyder 8120100C26 is a natural white polyethylene vertical storage tank, 86 inches across and 72 inches tall, holding 1,500 gallons at 270 pounds. It is the 1,500 that goes under an eight foot ceiling with the 18 inch threaded, vented manway still opening from a step, the middle shape between the low tanks below it and the tall 1,300 in this family. Its wall is rated for a specific gravity of 1.9, or 23,769 pounds of contents against 12,510 for water, so it holds concentrated acid, ferric and the heavy brines at strength, and the white wall shows the level through it in daylight. A 2 inch polypropylene female NPT bulkhead outlet, a 3 year warranty, and freight at class 400 from Marked Tree, Arkansas.
Want a second opinion on the size? Call 866-418-1777 with the daily draw and the delivery interval, or price freight to your ZIP and add it to your cart above.
A truck's worth of chemical, and the vent it needs
At 1,500 gallons a tank stops being filled from totes and starts being filled from a truck, and the thing a truck fill changes is the vent: a delivery pump pushes air out faster than a screened cap passes it, and a tank that cannot breathe out bulges. The atmospheric vent capacity guide works the arithmetic for tanks from this size up, for filling, emptying and the daily breathing a tank does on its own. Full at the rating it puts 23,769 pounds on an 86 inch circle, and a rotationally molded floor bears on all of it, so it stands on a slab in full contact per the concrete pad sizing guide, inside a berm sized to the tank when the liquid is regulated, with the empty tank strapped against wind. The tank sizing calculator turns feed rate and delivery interval into a volume, and the tank sizing guide covers the reserve to keep the pump wet between deliveries.
Grades on the 86 x 72 inch tank, and the 1,300 and 1,550 beside it
| Part | Gallons | Diameter x height | Empty weight |
|---|---|---|---|
| 8120100C26 (this tank, 1.9 SG) | 1,500 | 86 x 72 in | 270 lb |
| 1770000C34 (black) | 1,500 | 86 x 72 in | 260 lb |
| 1770000N42 (XLPE) | 1,500 | 86 x 72 in | 260 lb |
| 1770000N48 | 1,500 | 86 x 72 in | 260 lb |
| 1830400N40 (tall) | 1,300 | 72 x 87 in | 290 lb |
| 1840000C26 (tall) | 1,550 | 64 x 124 in | 335 lb |
The 1770000 family is the same 1,500 gallons in the same shell, black in the C34, cross-linked for oxidizers in the N42 and the other chemical grade in the N48, listed ten pounds lighter on the sheet. The 1830400N40 stands 1,300 gallons on a 72 inch base at 87 inches, and the 1840000C26 puts 1,550 gallons on a 64 inch base at 124 inches for a site with height and no floor.
Not sure which one? Tell us the liquid, the site and the ceiling height at 866-418-1777, or request a written quote with freight to your ZIP.
Outlet, manway, vent
- Outlet: 2 inch polypropylene female NPT bulkhead fitting, at the base; a flanged transition, a flexible connector to hard pipe, and the valve supported off the pad in the material the chemical calls for.
- Access: 18 inch threaded, vented manway, 72 inches up, reached from a step; fill from a truck through a dip tube to the floor so the liquid does not free-fall and foam, vent outside on anything that fumes, and size the vent for the delivery pump.
- Service limit: 120 F / 48 C.
Six feet of liquid above the outlet keeps a pump's suction flooded to the last inches; mount the pump below the outlet so it primes by gravity, and put a low-level float on it. The level shows through the white wall. Keep the manway closed against vapor loss, label the one chemical the tank holds, and where it freezes, wrap or trace the outlet valve and the first pipe run; the body takes ice from the top down without harm.
Plants that take a truck
The coagulant or the caustic tank at a water plant that takes a partial tanker, the acid supply at a cooling tower, the bulk tank behind a chemical feed skid, the makeup tank on a plating line, and a fertilizer solution tank on a farm. Not a fire tank; the fire-water reservoir design guide wants a water wall at this size. Where a reuse system doses treatment chemical between storage stages, the industrial water reuse tank topology article shows where a tank this size sits in the train.
Freight from Marked Tree, and the first delivery
The 8120100C26 ships from Marked Tree, Arkansas as LTL freight at class 400, the class light, bulky tanks take; the freight cost estimator quotes it to your ZIP, and the listed price is before freight. A forklift with long forks sets 270 pounds on the pad, or three people walk it empty; at 86 inches across it goes through a roll-up door or around the building. Fill it with water to the manway once and look at the outlet fitting and the pad edge, then drain and dry before the chemical goes in. Watch the first truck delivery from the first gallon to the last, and the log takes the date and strength of every load after it. Chalk the full-water line on the outside after the first fill; it is the level every later reading gets checked against.
Freight and documents
Ships from: Marked Tree, AR. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 8120100C26.
See this tank
Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).
Ready to order?
Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.