Five hundred and ten pounds, ten and a half feet, rated 1.35: the light tall 3,000
Where the floor is small and the liquid is light, the Snyder 5130000N33 is the 3,000 gallon tank to buy: 90 inches across, 127 inches tall, 510 pounds, the lightest wall in the shell, black polyethylene rated for a specific gravity of 1.35 on its sheet, which is 35,028 pounds of contents against 25,020 pounds of water. It comes out of Lincoln, Nebraska or Philippi, West Virginia, carries an 18 inch threaded, vented manway at ten feet seven inches, a service limit of 120 F / 48 C, a 3 year warranty, and freight at class 400.
Replacing a tank that failed? Call 866-418-1777 with what it held and how long it lasted; or check freight to your ZIP and put the 3000 gallon tank in your cart above.
Lincoln and Philippi, and what a light tank costs to move
A tank that weighs 510 pounds and stands ten and a half feet is freight by the cube, not the pound, and the sheet classes it at 400. Two plants keep the lane short: Lincoln for the plains, the Midwest and the Southwest, Philippi for the Atlantic states and the Southeast, and the freight cost estimator prices whichever serves your ZIP, with the listed price before freight. The tank is the tall shape at its lightest. A 90 inch circle is the smallest floor a 3,000 gallon Snyder vertical stands on, which is why it goes between two tanks that are already there or behind a building, and the 1.35 wall is the rating for water, rainwater, most fertilizer solutions and the light process liquids; it is not the wall for coagulants or strong acids, and the shell is molded in heavier walls for those. Full at the rating it puts 35,028 pounds on that 90 inch circle through a floor that bears across the whole pad, so the slab is engineered per the concrete pad sizing guide, level and in full contact, inside a berm sized to the tank where the liquid is regulated. Empty, ten and a half feet of black polyethylene on a seven and a half foot base is a sail, and a light one; strap it to structure before the first fill and look at the straps after the first windy week and the first full summer. Black polyethylene absorbs the ultraviolet that ages a white wall, keeps light and algae out of stored water, runs warmer in the sun than white, and hides the level, so a sender read at the ground is the gauge. Take 3,000 gallons to the tank sizing calculator against the draw between deliveries, and the reserve and the warm-weather headspace to the tank sizing guide.
Lightest of five on the 90 inch base
| Part | Gallons | Diameter x height | Empty weight |
|---|---|---|---|
| 5130000N33 (this tank, black, 1.35 SG) | 3,000 | 90 x 127 in | 510 lb |
| 5130000C34 (black) | 3,000 | 90 x 127 in | 575 lb |
| 5130000C37-BLACK (black) | 3,000 | 90 x 127 in | 575 lb |
| 5130000N40 (natural) | 3,000 | 90 x 127 in | 575 lb |
| 8390000C26 (low) | 2,650 | 102 x 97 in | 510 lb |
| 32288 (white) | 3,500 | 96 x 125 in | 550 lb |
The C34 and C37-BLACK are the other black tanks in this shell at 575 pounds, each rated as its own sheet says, and the N40 is the natural tank at the same weight, for a liquid that does not mind light and an operator who wants to see the level. Among them, this tank is the one for a light liquid on a small circle, and the shell's heavier walls are listed separately for the dense chemicals. The 8390000C26 lays 2,650 gallons down to 97 inches on a 102 inch base for a roof this tank cannot clear; the 32288 is the white 3,500 on a 96 inch base at 125 inches, two inches shorter, for a site with a little more floor and a lot of daylight.
Want the certified one or the plain one? Call 866-418-1777 and say what the inspector asks for; or request a quote on the row you need.
Reaching a lid at 127 inches on a light tank
- Manway: 18 inch threaded, vented, at 127 inches. A platform with a rail reaches it, and on a 510 pound tank the platform stands on its own legs, never on the tank; a tank this light moves under a person's weight. Fill through a dip tube to the floor, size the vent to the delivery pump or open the lid for the fill with someone at it, screen the vent, and run it outdoors on a liquid that fumes.
- Outlet: the outlet field on the sheet reads 15, and we print it as the sheet gives it. Name the liquid at order and the bulkhead fitting, gasket and bolting are matched to it, with a flexible connector to hard pipe and the first valve supported off the pad.
- Service limit: 120 F / 48 C.
Ten feet of head keeps a pump below the outlet flooded to the last few inches; a low-level float stops it before it draws air. A 1.35 wall is the thinnest in the shell, so the pipe run never carries its movement back into it: flexible connector, supported valve, no exceptions. The lid stays on between deliveries, the wall names the one liquid inside, and the band of wall above the liquid line gets a light at every opening, because vapor works on the thinnest wall first. Where it freezes, the valve and the first pipe run get trace heat or insulation; the body ices from the top down.
Water, rainwater and fertilizer on a seven and a half foot circle
A farm storing rainwater or well water beside the shop in a black wall that keeps algae out, a co-op with a fertilizer solution on a tight pad, and a plant with a light process liquid that wants the smallest floor for 3,000 gallons. Where site rules call for a second wall, the Captor double wall freeboard guide works through what a contained tank of this size gives up in usable volume. It is rated for water, but a fire reserve is sized and plumbed as its own system; the fire-water reservoir design guide covers what that takes before you buy this tank for it. Where a reuse system holds grey water or a light treatment chemical between stages, the industrial water reuse tank topology article shows where a tank this size sits in the train.
Light freight at class 400 out of Nebraska or West Virginia
The 5130000N33 ships from Lincoln or Philippi as freight at class 400 as the sheet lists it; at 90 inches across and 127 inches long on the deck it rides on a flatbed, and the freight cost estimator prices the lane to your ZIP, with the listed price before freight. A forklift with long forks sets 510 pounds on the pad with the forks under the body, never through the manway, and the straps to structure go on before the forklift leaves; a light tall tank does not stand unstrapped for an afternoon. Fill it with water to the shoulder once and hold it, watching the pad edge and the outlet fitting, then drain and dry before the liquid arrives. Read the serial number off the shell into the log the day it lands, not the day the warranty question comes up. Keep one spare gasket for the outlet fitting on the shelf; it is the part that fails on a holiday.
Freight and documents
Ships from: Lincoln, NE; Philippi, WV. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 5130000N33.
See this tank
Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).
Ready to order?
Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.