Sixty gallons, cross-linked, listed at 58 inches and 108 pounds
Here is what Snyder's sheet says about the SII-5680023CF42, printed as it stands: a 60 gallon chemical feed station tank in white cross-linked polyethylene, 47 inches long, 36 inches wide, 58 inches tall, 108 pounds empty, molded at Marked Tree, Arkansas. It is a CF part number, which is the tank-only line in this family, and it is listed at the same height and weight as the stand versions beside it. The wall is rated at a specific gravity of 1.9, so the sheet gives 500 pounds for 60 gallons of water at 8.34 pounds per gallon and 951 pounds of max contents. Access is a 6 inch lid and the service limit is 120 F / 48 C. No outlet size, no inlet size and no warranty term are published, so this page states none.
Is this the right 60 gallon tank? Call 866-418-1777 with the liquid, the site and the ceiling height, or get freight to your ZIP and add it to your cart above.
What leaves Arkansas, and what the sheet says is as shipped
Two things decide this purchase and both are on the paperwork. The first is the lane. Marked Tree, Arkansas is the plant, the sheet gives the freight class as LTL under NMFC 156600-02, and the package is 47 by 36 by 58 inches at 108 pounds: an ordinary pallet, no permit, no oversize move, a short run into the Mid-South and a sensible one elsewhere. On a station this size the lane often costs more than the tank does, which is why we put it in front of the specification rather than at the bottom of the page. The second is what the sheet actually lists, and here it pays to be exact. This is a CF part number listed at 58 inches and 108 pounds, the same height and weight the sheet gives the two CFWS stand parts, while the other CF part number is listed at 42 inches and 79 pounds. We print those figures as given and we do not interpret them: we will confirm, in writing, exactly what is supplied against this part number before your order ships, because on a feed station the difference between a vessel on the floor and a vessel carried up is the difference between a pump on a flooded suction and a pump fighting for prime. Whatever arrives, the floor under it is the same job: flat, level, continuous, carrying 500 pounds of water at full and 951 pounds at the sheet's own rating, with nothing under one corner. Measure four feet ten inches plus the pallet against the dock, the door and the header before the truck is booked. And size the vessel to the duty before any of that, using the tank sizing calculator for the dosing rate and the delivery interval and the tank sizing guide for the reserve and the thermal freeboard.
Two tank-only part numbers at two listed heights
| Part | Volume | Length x width x height | Empty weight |
|---|---|---|---|
| SII-5680023CF42 (this one, cross-linked, tank only) | 60 gal | 47 x 36 x 58 in | 108 lb |
| SII-5680023CF45 (the 45 part number, with basin) | 60 gal | 47 x 36 x 42 in | 79 lb |
| SII-5680024CFWS42 (cross-linked, with stand) | 60 gal | 47 x 36 x 58 in | 108 lb |
| SII-5680024CFWS45 (with stand, the 45 part number) | 60 gal | 47 x 36 x 58 in | 108 lb |
| SII-5690103CF42 (larger, cross-linked) | 90 gal | 56 x 43 x 41 in | 99 lb |
| SII-1170000W94301 (operator tank with lid) | 50 gal | 38 x 19 x 23 in | 25 lb |
The two CF part numbers are the tank-only line and they are listed differently: this one at 58 inches and 108 pounds, the 45 at 42 inches and 79 pounds with a containment basin named on it. That is the sheet's own record and it is the honest comparison to put in front of you, rather than a story about why. What this page can tell you with confidence is the wall. This is the cross-linked polyethylene part number rated at a specific gravity of 1.9 with a 120 F / 48 C limit, and those figures are this sheet's. The 45 numbers in the same family are listed in high density linear polyethylene and carry their own ratings on their own pages. Choose on the chemical and the handling, and when the liquid is a hard one tell us before you order so we can put Snyder's own guidance against both walls. The two CFWS numbers are the versions to buy where a metering pump has to live below the draw-off. For a bigger interval between deliveries, the cross-linked 90 gallon SII-5690103CF42 is listed at 56 by 43 inches and 41 inches tall at 99 pounds; the 50 gallon part in the last row is a portable operator tank from a different family and no dosing duty is claimed for it.
Comparing across brands too? Call 866-418-1777; we carry Norwesco, Snyder, Chem-Tainer, Enduraplas and Bushman and will say which one fits, or price the freight first.
The lid is 6 inches and everything goes in through it
- The opening: a 6 inch lid is the only access this sheet publishes. Every delivery, every sample and every rinse goes through it, so the fill line ends at a fixed coupling rather than a hose in somebody's hand, and the vent path through the lid stays clear whenever a pump draws. A blocked vent and a running pump will pull a polyethylene wall inwards, cross-linked or not.
- What it is not: an opening to clean through with an arm and a brush. Build the wash-out routine around a 6 inch port before the first chemical goes in.
- The draw-off: no outlet size and no inlet size are published on this sheet, so this page prints neither. Name the chemical and the flow when you order and we confirm the fitting, the gasket and the valve against Snyder's drawing for this part number before anything ships.
- Valve and supports: the valve rides on its own bracket off the floor or the wall, the first joint is a flexible connector, and a union or flange downstream takes any future valve change away from the tank fitting. Nothing rigid is clamped between the vessel and a pipe run.
- Pump and protection: short, falling suction run, first bend clear of the fitting, a strainer that can be cleaned without breaking the line, and a low level cut-out that stops the pump with liquid still over the draw-off.
Put the level on a gauge and the identity on the tank, in that order, on the day it is commissioned. The level gauge selection guide compares the technologies that survive chemical service, and the tank label and signage guide covers the marking that stands up when somebody official walks the plant room. Neither is expensive, and both are cheaper than the incident that happens when a station is unlabelled and its level is a guess.
A feed station for a plant that has its own frame
A tank-only part number is what gets specified where the plant has already solved the mounting: a skid built by the process contractor, a plinth poured with the building, a mezzanine deck, an existing bund the vessel drops into, or a frame carried over from the station this one replaces. The duties are the ordinary chemical ones at 60 gallons: hypochlorite, caustic, acid or polymer feed at a small water or wastewater works, a sanitiser day tank on a food or dairy line, cooling tower treatment, detergent or acid at a wash, a dosing point in a finishing shop. Whichever it is, the number that matters day to day is strength rather than volume, and a sample drawn without a protocol produces a wrong answer that reads like a right one; the chemical sampling protocol article is how to avoid that.
Listed chemical service for this shell
The maker's list for this resin: each liquid, the concentration it is rated to, and the fitting and gasket that go on the order. Verify your own service on the linked page or in the chemical compatibility database before ordering.
- Acetic Acid (60%) - PP/PVC fittings, EPDM gaskets
- Aluminum Sulfate (50%) - PVC fittings, EPDM gaskets
- Calcium Chloride (40%) - PVC fittings, EPDM gaskets
- DEF (32.5%) - 316SS fittings, EPDM gaskets
- Ethylene Glycol (100%) - PVC fittings, EPDM gaskets
- Ferric Chloride (50%) - PVC fittings, EPDM gaskets
- Ferric Sulfate (60%) - PVC fittings, EPDM gaskets
- Ferrous Sulfate (20%) - PVC fittings, EPDM gaskets
- Hydrofluosilicic Acid (26%) - PP/PVC fittings, Viton gaskets
- Magnesium Chloride (30%) - PVC fittings, EPDM gaskets
- Polyaluminum Chloride - PVC fittings, EPDM gaskets
- Potassium Carbonate (50%) - PVC fittings, EPDM gaskets
- Potassium Hydroxide (saturated) - PVC fittings, EPDM gaskets
- Propylene Glycol - PP/316SS fittings, EPDM gaskets
- Sodium Carbonate (30%) - PVC fittings, EPDM gaskets
- Sodium Thiosulfate (40%) - PVC fittings, EPDM gaskets
- Urea Solution (50%) - PP/PVC fittings, EPDM gaskets
One hundred and eight pounds on an LTL lane, before freight
The sheet gives the freight class as LTL under NMFC 156600-02, out of Marked Tree, Arkansas, shipping at 47 by 36 by 58 inches at 108 pounds. The freight cost estimator prices that lane to your ZIP, and the listed price is before freight. Have the lift or the second pair of hands arranged for the delivery slot rather than the afternoon after, and have the route measured: the dock lip, the doorway and the lowest header between them. Set the vessel in its final position on level floor, connect nothing yet, fill it with clean water and hold it while you read the base, the lid seal and each joint, then drain it dry before the chemical is ordered. If anything about what arrives does not match the height and weight on this page, call us the same day and we will settle it against Snyder's own paperwork rather than leaving you to work it out on the floor. Write the fill date on the manway with a paint marker; it answers the first question anyone asks about a tank.
Freight and documents
Ships from: Marked Tree, AR. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 5680023CF-42.
See this tank
Product video. Watch the Snyder Industries 60 Gallon XLPE Chemical Feed Station Tank in White video (77 seconds) with dimensions, fittings and shipping notes.
Ready to order?
Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.