Skip to main content

Snyder Industries

Snyder Industries 2000 Gallon HDPE Vertical Liquid Storage Tank with ASTM Certification

$4,488.99
0
(No reviews yet) Write a Review
Adding to cart… The item has been added
SKU:
SII-5050300N45
Availability:
In Stock - Ships from nearest manufacturing plant
Weight:
500.00 LBS
Width:
96.00 (in)
Height:
84.00 (in)
Depth:
96.00 (in)
Capacity:
2000 Gallons
Material:
Polyethylene
Color:
White
Diameter:
96"
Lid/Manway:
18" Threaded Vented Manway
Specific Gravity:
1.9
Max Temperature:
120 F/ 48 C
Certifications:
3492,2285,2282
Warranty:
3 Year Warranty
Freight Class:
LTL
NMFC Code:
156600-01
Manufacturer Part Number:
5050300N45
Manufacturer:
Snyder Industries
Technical Drawing:
https://onesourceplastics.com/content/tech-drawings/sii-5050300n45.pdf
Ship Weight:
500 lb
Ship Dimensions:
96" L x 84" W x 84" H (crated)
Specific Gravity Rating:
1.9
Lid Size:
18"

2,000 gallons at 1.9 specific gravity on a 96 inch base, ASTM certified

The Snyder 5050300N45 is a white polyethylene vertical liquid storage tank, 96 inches across and 84 inches tall, holding 2,000 gallons at 500 pounds. Its wall is rated for a specific gravity of 1.9, or 31,692 pounds of contents against 16,680 for water, the chemical-grade wall for ferric chloride at strength, concentrated acids and the heavy brines, it is sold with ASTM certification for jobs that need the paper, and at 500 pounds it carries the most resin of any 2,000 gallon tank Snyder makes. The manway is 18 inches, threaded and vented, the warranty is 3 years, and it ships LTL.

Is this the right 2000 gallon tank? Call 866-418-1777 with the liquid, the site and the ceiling height, or get freight to your ZIP and add it to your cart above.

The heaviest 2,000, certified, under seven feet

A 1.9 specific gravity wall is sized for a liquid nearly twice as dense as water, and 500 pounds of resin is what that takes on this wide, low shell, 80 pounds more than the certified 1.5 wall beside it. The certification is against ASTM D1998; the HDPE tank wall thickness guide explains the sizing logic and why the headspace is where a wall ages, and the freeboard sizing guide works out the usable volume once thermal expansion, which is large for a dense chemical, is accounted for. At 2,000 gallons the vent has to keep up with the pump-out and the fill, so it is sized for them; the atmospheric vent capacity guide carries the API 2000 worked examples. Full, it puts 31,692 pounds on a 96 inch circle at the rating, which a slab in full contact carries, and the low shape puts it there without a lever arm. The tank sizing calculator sizes the tank to feed rate and delivery interval, and the tank sizing guide covers the reserve.

Grades on the 96 x 84 inch tank, and the sizes beside it

Snyder vertical tanks, 1,900 to 2,500 gallons
PartGallonsDiameter x heightEmpty weight
5050300N45 (this tank, 1.9 SG, ASTM certified)2,00096 x 84 in500 lb
5050300N43 (1.5 SG, ASTM certified)2,00096 x 84 in420 lb
5050300N42 (XLPE, 1.9 SG)2,00096 x 84 in420 lb
5050300N39 (1.35 SG, ASTM certified)2,00096 x 84 in380 lb
5050000N45 (1.9 SG, ASTM certified)2,00090 x 88 in400 lb
1780200N40 (tall, XLPE)1,90072 x 119 in445 lb
5090000C262,50090 x 107 in450 lb

The N43 and N39 are the certified 1.5 and 1.35 walls in this same shell for coagulants, brines and water that never approach this density, and the N42 is cross-linked polyethylene for oxidizers. The 5050000N45 is this same certified 1.9 wall on a 90 inch base 4 inches taller and 100 pounds lighter. The 1780200N40 stands 1,900 gallons on a 72 inch base for a narrow corner, and the 5090000C26 is the 2,500 gallon tank on a 90 inch base at 107 inches.

Comparing across brands too? Call 866-418-1777; we carry Norwesco, Snyder, Chem-Tainer, Enduraplas and Bushman and will say which one fits, or price the freight first.

Bulkheads and lid

  • Access: 18 inch threaded, vented manway; vent outside on acid and caustic service, fill through a dip tube, and size the vent for a delivery truck's unload rate.
  • Outlet: name the chemical when ordering so the bulkhead fitting matches it; hard pipe joined to the bulkhead through a flexible connector, valve on a bracket of its own.
  • Service limit: 120 F / 48 C.
  • Listing: ASTM certification.

Choose the level sender for the chemical; a float switch at low level shuts the pump off before it runs dry. Put the dosing pump below the outlet, where it primes by gravity, keep the manway closed against vapor loss, and shade the tank where the chemical is light-sensitive. A single wall tank of a regulated liquid lives inside a berm that holds the whole tank. Insulate or drain the outlet valve and the first run of pipe wherever the ground freezes.

Receiving a delivery

A delivery truck's pump moves liquid faster than a manway vent passes air, so the vent is sized for the unload rate or the fill comes in through a top bulkhead with its own vent line. The fill pipe runs to the floor so caustic or coagulant does not free-fall and foam. Dense liquids heat up when diluted, so a tank topped off with water for a batch is filled water first, chemical second, never the other way. The first delivery into a new tank is watched from start to finish, with the outlet fitting checked as the level climbs, and every delivery after that goes in the log with a date and a strength.

Day-to-day duty

Ferric and other dense coagulants at a small plant with a berm and a low roof, acid feed for pH control, heavy brine for a softener bank, and any 2,000 gallon vessel of dense chemical where the certification has to be on file, including a fire reserve of the kind the fire-water reservoir design guide describes when it holds water. One chemical per tank, labeled.

From the plant to your site

The 5050300N45 ships palletized as LTL freight (NMFC 156600-01) at a class rate; the freight cost estimator quotes it to your ZIP, and what is listed here is the price before freight. A forklift with long forks sets 500 pounds on the pad, and at 96 inches across it needs a gate, not a door. Water-fill it once to the manway, hold it, then drain and dry before the chemical connection is made, and keep the certification paperwork with the project file. Write the fill date on the manway with a paint marker; it answers the first question anyone asks about a tank.

Freight and documents

Ships from: Chowchilla, CA. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.

Technical drawing (PDF) for Snyder Industries 5050300N45.

See this tank

Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).

Ready to order?

Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.

Adding to cart… The item has been added