7,900 gallons at 1.9 specific gravity on a ten foot base, ASTM model
The Snyder 7370000N45 is a white polyethylene vertical liquid storage tank, 120 inches across and 177 inches tall, holding 7,900 gallons at 1,900 pounds. Its wall is rated for a specific gravity of 1.9, or 125,183 pounds of contents against 65,886 for water, the chemical-grade wall for ferric chloride at strength, concentrated acids and the heavy brines, it is one of Snyder's ASTM models, and the ten foot base takes a tanker load of dense chemical and a full reserve under a fifteen foot roof. An 18 inch manway, threaded and vented, sits on top; a 3 year warranty comes with it; oversize freight brings it.
Want it on the pad this month? Check freight to your ZIP, add it to your cart above, and 866-418-1777 will confirm the ship date.
Sixty tons of chemical on a ten foot circle
A 1.9 specific gravity wall is sized for a liquid nearly twice as dense as water, and the ASTM D1998 design is what says the wall was sized that way; the HDPE tank wall thickness guide explains the sizing logic and why a wall this tall is inspected from the top, in the headspace. Full, it puts 125,183 pounds on a 120 inch circle at the rating: a designed slab that touches every inch of the floor, following the concrete pad sizing guide, inside a berm sized to the tank, a wind strap on the empty tank, and access to the manway from a fixed platform with a rail. The tank sizing calculator turns feed rate and delivery interval into a volume, and the tank sizing guide covers the reserve, which for a dense chemical includes freeboard for thermal expansion.
Grades on the 120 x 177 inch tank, and the sizes beside it
| Part | Gallons | Diameter x height | Empty weight |
|---|---|---|---|
| 7370000N45 (this tank, 1.9 SG, ASTM model) | 7,900 | 120 x 177 in | 1,900 lb |
| 7370000N43 (1.5 SG, ASTM model) | 7,900 | 120 x 177 in | 1,900 lb |
| 7370000N42 (XLPE) | 7,900 | 120 x 177 in | 2,700 lb |
| 7370000N46 | 7,900 | 120 x 177 in | 2,700 lb |
| 7370000N40 (XLPE) | 7,900 | 120 x 177 in | 2,700 lb |
| 5300600N45 (1.9 SG, ASTM model) | 8,000 | 120 x 186 in | 2,300 lb |
| 5300600N40 (XLPE) | 8,000 | 120 x 186 in | 1,900 lb |
| 5300700C26 (low profile) | 7,650 | 142 x 122 in | 1,400 lb |
The N43 is the 1.5 wall in this same shell at this tank's weight for coagulants and brines that never approach this density; the N40 and N42 are cross-linked polyethylene for oxidizers and the N46 another linear grade, all listed at 2,700 pounds. The 5300600 tanks hold 8,000 gallons on this base 9 inches taller, the N45 this same 1.9 wall in a heavier shell, and the 5300700C26 lays 7,650 gallons down on a 142 inch base at 122 inches for a barn roof.
Which wall for your chemical? Call 866-418-1777 with the name and the concentration and we will pick the row.
Ports
- Access: 18 inch threaded, vented manway, 177 inches up; a dip tube for the fill, an outdoor vent on acid and caustic, and vent capacity to match the tanker.
- Outlet: tell us the chemical when ordering and the bulkhead fitting is matched to it; a flanged transition, an expansion joint, and a valve supported off the slab.
- Service limit: 120 F / 48 C.
- Snyder line: ASTM.
Pick a level sender rated for the chemical and bring its reading to ground level, so the number never needs a climb; keep the manway shut against vapor loss and shade a light-sensitive chemical. Put a regulated chemical in a single wall tank and the berm around it has to hold all of it. Where it freezes, insulate or drain the outlet valve and the first length of pipe.
Filling from a tanker
Unloading a tanker pushes air out faster than a stock manway vent can pass it; size the vent for that rate, or fill through a dedicated top bulkhead vented separately. Run the fill pipe to the floor so caustic or coagulant does not free-fall and foam. Diluting a dense chemical makes heat, so a batch is built water first and chemical second, never the reverse. The first tanker into a new tank is a supervised job, slab edge and outlet fitting checked as it fills, and from then on each load is logged by date and strength.
Where you will find one
Ferric and other dense coagulants at a plant with a berm, acid feed for pH control, heavy brine at plant scale, dense process chemicals from a tanker with a full reserve, and water where the buyer wants the heaviest wall for a long life outdoors, including a fire reserve of the kind the fire-water reservoir design guide describes. One chemical per tank, labeled for both inspectors at once.
Shipping the tank
At 120 inches across and 177 inches long on the deck the 7370000N45 is oversize freight (NMFC 156600) on a flatbed at a lane rate; the freight cost estimator prices it for your ZIP, and the listed price is before freight. A crane sets 1,900 pounds upright on the slab; unloading is a forklift job, standing it is not. Water-fill it once to the manway, hold it, then drain and dry before the chemical connection is made. Walk the base after the first hard rain; a pad that shifts shows it at the edge first.
Freight and documents
Ships from: Lincoln, NE. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.
Technical drawing (PDF) for Snyder Industries 7370000N45.