Skip to main content

Snyder Industries

Snyder Industries 3000 Gallon HDPE Vertical Liquid Storage Tank with ASTM Certification

$5,806.84
0
(No reviews yet) Write a Review
Adding to cart… The item has been added
SKU:
SII-8160000N43
Availability:
In Stock - Ships from nearest manufacturing plant
Weight:
675.00 LBS
Width:
90.00 (in)
Height:
127.00 (in)
Depth:
90.00 (in)
Capacity:
3000 Gallons
Material:
High Density Linear Polyethylene
Color:
White
Diameter:
90"
Lid/Manway:
18" Threaded Vented Manway
Specific Gravity:
1.5
Max Temperature:
120° F / 48° C
Certifications:
FDA-compliant resin
Warranty:
3 Year Warranty
Freight Class:
OVS
Manufacturer Part Number:
8160000N43
Manufacturer:
Snyder Industries
Technical Drawing:
https://onesourceplastics.com/content/tech-drawings/sii-8160000n43.pdf
Ship Weight:
675 lb
Ship Dimensions:
90" L x 127" W x 127" H (crated)
Specific Gravity Rating:
1.5
Lid Size:
18"

3,000 gallons at 1.5 specific gravity on a 90 inch base

The Snyder 8160000N43 is a white high density linear polyethylene vertical liquid storage tank, 90 inches across and 127 inches tall, holding 3,000 gallons at 675 pounds. Its wall is rated for a specific gravity of 1.5, or 37,530 pounds of contents against 25,020 for water, so it holds brine, fertilizer solution and coagulant as delivered as well as water, and the seven and a half foot base puts a tanker's partial load under an eleven foot roof with the 18 inch threaded, vented manway reached from a short platform. A 3 year warranty, and it ships as oversize freight.

Buying for a site, a fleet or a district? Request a written quote with freight to your ZIP, or add it to your cart above and call 866-418-1777 with any question on the fit.

Three thousand gallons in the middle wall

A water-rated wall is for water and nothing heavier; the chemical-grade wall is for concentrated acid; a 1.5 wall is the middle, sized for brine, fertilizer solution and coagulant as delivered and every water application, with margin, and 675 pounds of resin is what that takes on this shell, 65 more than the 1.35 wall beside it. Rotationally molded polyethylene tanks are sized to ASTM D1998, and the way a tank meets the density it is rated for is in the wall; the HDPE tank wall thickness guide explains the sizing logic and why the headspace is where a wall ages. Full, it puts 37,530 pounds on a 90 inch circle at the rating, which a slab in full contact carries, with the empty tank strapped against wind. Our 3,000 gallon vertical tank buyers guide sets the makers' shapes at this volume side by side; the tank sizing calculator tells you whether 3,000 gallons covers the draw, and the tank sizing guide covers days of supply.

Grades on the 90 x 127 inch tank, and the sizes beside it

Snyder vertical tanks, 2,650 to 3,500 gallons
PartGallonsDiameter x heightEmpty weight
8160000N43 (this tank, 1.5 SG)3,00090 x 127 in675 lb
8160000N39 (1.35 SG)3,00090 x 127 in610 lb
5130000C37-BLACK (black)3,00090 x 127 in575 lb
5130000C343,00090 x 127 in575 lb
5130000N333,00090 x 127 in510 lb
32288 (water)3,50096 x 125 in550 lb
8390000C26 (low profile)2,650102 x 97 in510 lb

The N39 is the 1.35 wall in this same shell, 65 pounds lighter, for alum and the lighter solutions; the 5130000 tanks are the general grades, the C37-BLACK in black for sun and the N33 a lighter linear grade. The 32288 is the water tank at 3,500 gallons on a 96 inch base at this height, and the 8390000C26 lays 2,650 gallons down to 97 inches on a 102 inch base.

Comparing against another maker? Send the competing spec to 866-418-1777 or a quote request and we will show the differences honestly.

Top and bottom connections

  • Access: 18 inch threaded, vented manway, 127 inches up; filled by hose, tote pump or truck through a dip tube, vented outside on anything that fumes, and size the vent for the delivery pump.
  • Outlet: the bulkhead fitting is chosen for the liquid at order time; flex between the bulkhead and hard pipe, and a valve braced off the pad so the fitting carries no pipe weight.
  • Service limit: 120 F / 48 C.

The white wall shows the level in daylight; fit a sender read at ground level so nobody climbs for a number, and a low-level float switch keeps a pump from running dry. Put the pump below the outlet, where it primes itself, close the manway against vapor loss, and keep a light-sensitive liquid out of direct sun. In a freezing climate insulate or drain the outlet valve and the first run of pipe; the body takes ice from the top down without harm.

First load in

A delivery truck's pump can push air out faster than a stock vent can pass it, so the vent is sized for the unload rate or the fill goes through a dedicated top bulkhead with its own vent line. The fill pipe reaches the floor, so the liquid enters below the surface instead of free-falling and foaming. The first tanker into a new tank is a supervised job, slab edge and outlet fitting checked as it fills, and from then on each load is logged by date and strength.

The log entry

Once a season, with the tank as low as the schedule allows, open the manway in daylight and look at the headspace wall and the underside of the top for chalking, crazing or a change in color; that is where a polyethylene wall ages first, and the wetted wall below tells you nothing. Check the outlet fitting for a weep, the strap for tension, and the pad edge for a crack or a gap, and write the date and what was seen on the log.

Duty it is sized for

Coagulant, brine and fertilizer solution at farms and small plants, well storage for a house, a barn and a garden, a rain cistern under a large roof, stock water on a pasture, and a fire reserve of the kind the fire-water reservoir design guide describes. One liquid per tank, labeled.

Landing it on the pad

At 90 inches across and 127 inches long on the deck the 8160000N43 ships as oversize freight at a lane rate rather than a class rate; the freight cost estimator prices the lane to your ZIP; the figure listed here is before freight. A forklift with long forks sets 675 pounds on the pad. Fill it to the manway once, hold it, and check the outlet fitting before the pump goes on. Save the pallet; a tank that ever has to move again is easier to move on it.

Freight and documents

Ships from: Marked Tree, AR. LTL freight is quoted to your ZIP with the freight cost estimator or by phone at 866-418-1777. The listed price is before freight.

Technical drawing (PDF) for Snyder Industries 8160000N43.

See this tank

Interactive 3D model with live fill. This tank has an interactive 3D model built to its manufacturer dimensions. Rotate it, and set a fill level to see how much liquid it holds at any height. Open the 3D view on the product photo above. Download the 3D model (GLB).

Ready to order?

Add it to your cart at the top of this page, get LTL freight to your ZIP, request a written quote, or call 866-418-1777. The listed price is before freight.

Adding to cart… The item has been added